Design Guide

28
IMPORTANT
With 24" depth cabinets, the water line opening must be in the location as shown as there will not be room to route a
water line behind the appliance for risk of pinching.
With cabinets deeper than 24" there is room to fit the pipe behind the appliance and the wall so there are no
requirements for the water line lead out position.
Do not install the shut-off valve for the water supply behind the appliance, to allow access to the shut off without
having to pull out the appliance!
The appliance can be used freestanding or semi built-in.
If semi built-in, consider the cabinet opening dimensions specified below.
Minimum opening height for the single door 36" models (CS 2060 / CS 2061) is 80".
Minimum opening height for the french door 36" models (CS 2062 / CBS 2062) is 80-1/2" to accommodate the top
mounted hinges.
The requirements for water supply and electrical outlet are the same for both applications.
Free length of the power
cord is 90".
The electrical outlet
must not be situated
behind the appliance
and must be easily
accessible.
The power cord exits the
rear of the appliance just
above the opening for the
water line.
Freestanding/Semi Built In Models
Cabinet Opening Dimensions - 72" Models (Side by Side)
The water line lead out posi-
tion can be within the shaded
area.