Design Guide

27
Freestanding/Semi Built In Models
Cabinet Opening Dimensions - 36" Models
IMPORTANT
With 24" depth cabinets, the water line opening must be
in the location as shown as there will not be room to route
a water line behind the appliance for risk of pinching.
With cabinets deeper than 24" there is room to fit the
pipe behind the appliance and the wall so there are no
requirements for the water line lead out position.
Do not install the shut-off valve for the water supply
behind the appliance, to allow access to the shut off
without having to pull out the appliance!
Water line opening
Water supply line
Free length at least
31 - 1/2" (800 mm)
The cabinet opening height is 84" when using the
decorative grille. The decorative grille is available
as accessory and is not required for proper opera-
tion of the appliance. All ventilation requirements
are handled through the toe kick grille on the ap-
pliance and this decorative grille is intended to be
used as a filler for pre-existing 84" openings.
NOTE
The decorative upper grille attaches to the
cabinets / gables on either side of it and not to the
appliance itself nor any cabinet above.
The appliance can be used freestanding or semi built-in.
If semi built-in, consider the cabinet opening dimensions specified below.
Minimum opening height for the single door 36" models (CS 2060 / CS 2061) is 80".
Minimum opening height for the french door 36" models (CS 2062 / CBS 2062) is 80-1/2" to accommodate the top
mounted hinges.
The requirements for water supply and electrical outlet are the same for both applications.
Free length of the power
cord is 90".
The electrical outlet
must not be situated
behind the appliance
and must be easily
accessible.
The power cord exits the
rear of the appliance just
above the opening for the
water line.