Design Guide
31
Ventilation Requirements 36" and 72" (Side by Side) Models
CS/CBS 20 appliances dont need any ventilation openings in the cabinet. The
requiredairowisdirectedthroughthetoekickarea.
The cover grill provided with the appliance must be used
for the ventilation opening. This grill must not be covered
by toe kick or other trim.
CS/CBS 2082 CS 2080/2081
R600a Refrigerant
WARNING!
The refrigerant R600a contained within the
appliances is environmentally friendly, but
flammable. Leaking refrigerant can ignite.
To prevent possible ignition, designed
ventilation is required.
Freestanding/Semi Built In Models