Specifications

Unit Dimensions
Cabinet Opening Dimensions
Ventilation Requirements
IMPORTANT
Do not install the shut-
off valve for the water
supply behind the
appliance.
(CS 1660 only)
The water line lead out
position for CS 1660
models can be within
the shaded area.
CS 16..
H = 80" (2032 mm)
The appliance can be used freestanding or semi built-in. If semi built-in,
consider the cabinet opening dimensions.
The power cord comes out of the appliance top. The location of the electrical
outlet can be within a radius of 90 inch from the appliance top center.
A. 79-1/2" (2020 mm)
B. 29-3/8" (747 mm)
C. 24-13/16" (630 mm)
D. 52-3/8" (1330 mm)
E. 31-1/8" (791 mm)
Do not restrict the air fl ow. The opening can either be directly over the appliance , above the cabinet and
below the ceiling or through a vent installed in a so t .
The cabinet height as speci ed at 80" (2032 mm) will create a 1-5/16" (33 mm) gap above the appliance
providing optimal air fl ow over the top of the appliance for its e cient operation.
Be sure to consider the possibility of having to raise some of the leveling legs in order to level the appliance
when installing. If you adjust the height of the appliance - it will e ectively reduce air fl ow. Therefore leave
yourself some room for adjustment.
IMPORTANT
The section between the freezer door and the fl oor must not be covered.
The refrigerator is designed to allow proper air fl ow when the appliance is installed up against the wall.
A minimum space of 1 1/2" is required behind the cabinet when venting above an upper cabinet which
is installed fl ush to the top of the appliance.
B - Side view
Cabinet
Refrigerator
30"
Diagrams
Liebherr CS 1640B
Freestanding/Semi Built-in

Summary of content (2 pages)