Spec Sheet

Subject to modification. For up-to-date information, visit home.liebherr.com.
Unit Dimensions
Top Door Hinge Clearence
Assuming centerline
Overall height can be in-
creased by 1-1/2" (40 mm).
When installing CS 20 units into a row of cabinets or wall units, use these dimensions to achieve a custom
look with the cabinetry.
Consider the necessary clearance for the top door hinge with CS 20 units.
Cabinet Opening Dimensions Ventilation Requirements
CS 20 appliances dont need any ventilation openings in
the cabinet. The required air ow is directed through the
toe kick area.
It is important to use the provided cover grille for the
ventilation opening. This opening must not be covered
with a cabinet base.
Water line opening
Water supply line
Free length at least
31 - 1/2" (800 mm)
IMPORTANT
Do not install the shut-
off valve for the water
supply behind the
appliance.
The appliance can be used freestanding or semi
built-in. If semi built-in, consider the cabinet
opening dimensions speci ed below.
Minimum opening height for the french door
36" model (CS 2062) is 80-1/2"
to accommodate the top mounted hinges.
The requirements for water supply and electrical
outlet are the same for both applications.
IMPORTANT
With 24" depth cabinets, the water line opening must
be in the location as shown as there will not be room
to route a water line behind the appliance for risk of
pinching. Also, for this cabinet depth the electrical
outlet cannot be behind the unit or the unit will not be
able to be pushed all the way back into the opening.
With cabinets deeper than 24" there is room to t the
pipe behind the appliance and the wall so there are no
requirements for the water line lead out position.
The position of the electrical outlet can be within the grey
shaded areas or above the appliance.
A. 3-3564" (90 mm)
B. 79-5164" (2027 mm)
C. 35-5364" (910 mm)
D. 24-732" (615 mm)
E. 40-5364" (1037 mm)
F. 39-2964" (1002 mm)
36"
Diagrams
CS 2082
Freestanding/Semi Built-in

Summary of content (4 pages)