User Manual

5
IceMaker
The IceMaker is fitted in the freezer compartment of the
combined refrigerator-freezer. It must be connected to
the mains water supply to work.
The appliance must be levelled to ensure that all the
chambers in the ice-cube tray of the IceMaker are com-
pletely lled with water.
See the section entitled Water connection for
IceMaker for further details.
Requirements for installation
Check the following:
Is the oor designed to withstand the net weight of the
appliance plus the weight of complete contents?
The net weight of the appliances is as follows:
ECBN 5066 > 147 kg
EC(B)N 6156 > 163 kg
EC(B)N 6256 > 159 kg
Is the oor level?
IMPORTANT
Do not start the appliance for 1 hour
after transport so that the lubricant in the
compressor can collect in the compressor
housing and cannot get into the refrigerant
circuit.
Anti-tipping device
The anti-tipping bracket supplied with the appliance
must always be installed to prevent the appliance tipping
over when the fully loaded door is opened.
Range of appliance use
The appliance is suitable solely for storing food in a
domestic environment or similar.
This includes, for example, use:
- in private homes,
- in staff kitchenettes, bed and breakfast establish-
ments,
- by guests in cottages, hotels, motels and other forms
of accommodation,
- in catering and similar services in the wholesale
trade.
The appliance is not suitable for storing and cooling
medicines, blood plasma or laboratory preparations.
Incorrect use of the appliance can cause the stored
goods to be damaged or spoiled.
Furthermore, the appliance is not suitable for use in
explosion-hazard areas.
General notes
Climate rating
The climate rating indicates the room temperature at
which the appliance may be operated in order to achieve
full cooling capacity.
The climate rating for the appliance is shown on the type
plate.
Climate rating Ambient temperature
SN +10°C to +32°C
N +16°C to +32°C
ST +16°C to +38°C
T +16°C to +43°C
SN-ST +10°C to +38°C
SN-T +10°C to +43°C
IMPORTANT
Do not operate the appliance outside the
specified ambient temperature range.
The appliance's refrigerant circuit has been tested for
leaks.