Design Guide

Fully Integrated
24" Model: HC 1030, HC 1050B, HC 1070, HC 1080, HC 1021/ HCB 1060, SBS 6613
14
Ventilation Requirements
This is a fully integrated refrigerator-freezer which means that it
is fully enclosed by a kitchen cabinet. This type of cabinet must
be carefully constructed using the correct dimensions and it
must provide suitable ventilation to ensure proper appliance
operation.
NOTICE
If the following ventilation dimensions are
not observed the compressor will be dam-
aged.
Kitchen Cabinet Airflow
1. The following ventilation dimensions must be observed:
There must be a ventilation space at least 31 in.² (200 cm²)
at the airflow inlet (1) and at the airflow outlet (2).
The top ventilation space can be directed in one of the fol-
lowing ways:
A) Directly over the appliance (2) with either an optional fac-
tory air vent or custom made one.
B) Above the cabinet and below the ceiling (3).
C) Through a vent installed in a soffit (4).
A
B
C
A minimum space of 1 1/2" is required when a cabinet is built
above and/or underneath.
B - Side view
Cabinet
Refrigerator