Specifications Sheet

Unit Dimensions
Ventilation Requirements
Kitchen Cabinet Base Grille
Water Filter
A
B
C
B - Side view
Cabinet
Refrigerator
This is a fully integrated refrigerator-freezer which means that it is fully enclosed by a kitchen cabinet. This type
of cabinet must be carefully constructed using the correct dimensions and it must provide suitable ventilation to
ensure proper appliance operation.
NOTICE
If the following ventilation dimensions are not observed the compressor will be damaged.
Kitchen Cabinet Air ow
The following ventilation dimensions must be observed: There must be a ventilation space at least 31 in.²
(200 cm²) at the air ow inlet (1) and at the air ow outlet (2).
The top ventilation space can be directed in one of the following ways:
A) Directly over the appliance (2) with either an optional factory air vent or custom made one.
B) Above the cabinet and below the ceiling (3).
C) Through a vent installed in a so t (4).
A minimum space of 1 1/2" (38mm) is required when a cabinet is built above and/or underneath.
A. 21-7/16" (544 mm)
B. 69-11/16" (1770 mm)
C. 22" (559 mm)
D. 69-3/4" - 70-3/8" (1772 - 1788 mm)
E. min. 22" (560 mm) max. 22-3/4" (578 mm)
F. min. 21 5/8" rec. 22" (min. 550 mm, rec. 560 mm)
G. 21-5/8" (550 mm)
H. 1-5/8" (40 mm)
J. 27-3/8" (695 mm)
K. 24-3/4" (629 mm)
L. max. 3/4" (19 mm)
M. 9-21/32" (245 mm)
Power cord
Level
Fish line for power cord
3" of the cabinet needs to be fi nished as it can
be seen when the door is open.
In the case of Side-by-Side installation, two
appliances next to one another, build the
appliances into separate kitchen units.
Ventilation through the cabinet base at the bottom can be
achieved by installing the provided ventilation grille (3) or
via a ventilation opening of at least 31 in.² (200 cm²).
When using the provided ventilation grille (3), please
proceed as follows:
- In the cabinet base, cut out a ventilation opening that
is 17-23/32 in. (450 mm) in width and 2-7/32 in.
(56 mm) in height.
-
Insert ventilation (3) grille into the cabinet base cut-out (1).
- From the back side, slide the snap-fi ts (2) into the grille
until the hooks make contact with the cabinet base.
- Completely mount cabinet base (with ventilation grille and
snap-fi ts) to kitchen cabinet.
A minimum space of 1 1/2 in.
is required when a cabinet is
built above and/or underneath.
The water fi lter module can be purchased from your Liebherr
retailer or distributor.
It should be installed near the appliance in the cabinet, for
example, in the adapter cabinet above the appliance. To connect
the fi lter to the appliance, it may be necessary to make an
opening (C) in the fl oor of the adapter cabinet through which the
hoses will be routed. The maximum length of the water hose
is 98-7/16 ‘‘ (2.5 m). The fi lter cover must be installed during
assembly to leave su cient space around the fi lter module.
Maintain the dimensions shown in Fig. so that the fi lter can be
replaced and the cover can be removed.
A. 13/16in (20mm)
B. 3-15/16in (100mm)
C. 1-3/16in. x 3/8in. ( 30mm x10mm)
D. min. 4in (100mm)
24"
Diagrams
Liebherr HCB 1060
Fully Integrated/Seamless

Summary of content (2 pages)