Design Guide

9
Area Requirements
Verify the following:
• Floorscansupportrefrigerator’sweightplusapproxi-
mately 1200 pounds (544 kg) of food weight. Not
all Liebherr products are designed for 1200 pounds
(544 kg) of food. Some units are smaller and total
weights may vary.
• Finishedkitchenoorheightislevel.Refrigeratormust
beshimmedtotheoorlevel,orlevelled,tomake
sure, air vents are not obstructed.
• Removeanythingattachedtotherearorsidewalls
that can obstruct refrigerator opening.
• Cutoutdimensionsareaccurate.
• Electricaloutletisincorrectlocation.
Do not install this unit next to any other refrigerator or
freezer except another Liebherr model. Liebherr models
are designed to allow side by side installation. They are
equipped with a heating system to eliminate condensa-
tion when units are installed side by side. Installing this
unit next to any other refrigerator or freezer can cause
condensation or cause damage to the Liebherr unit.
IMPORTANT
To protect the refrigerator from possible damage,
allow the appliance to stand 1 hour in place before
turning the electricity on. This allows the refrigerant
and system lubrication to reach equilibrium.
Blocking For Safety
The anti-tip bracket must be installed to prevent the unit
from tipping after it is installed. Refer to chapter "Block-
ing For Safety" in the installation instructions.
Safety Regulations
The appliances and are designed to cool, freeze, store
food as well and make ice (if equipped).
The appliances are manufactured to operate within
specific ambient temperature limits according to its
climate rating.
The climate rating indicates the ambient temperature at
which the appliance may be operated in order to deliver
optimal refrigeration performance.
The climate rating for each model is visible in chapter
"Specifications".
Climate Rating Ambient Temperature
SN 50°F to 90°F (10°C to 32°C)
N 61°F to 90°F (16°C to 32°C)
ST 61°F to 100°F (16°C to 38°C)
T 61°F to 109°F (16°C to 43°C)
SN-ST 50°F to 100°F (10°C to 38°C)
SN-T 50°F to 109°F (10°C to 43°C)
IMPORTANT
Do not operate the appliance outside the specified
ambient temperature range.
- Refrigerant circuits are tested for leaks.
- The appliances complies with current safety
regulations
CAN/CSA C22.2 No.60335-1-11
UL 60335-1 Fifth Edition
CAN/CSA C22.2 No. 60335-2-24-06
UL 60335-2-24 First Edition