Installation Instructions For Fully Integrated NoFrost Combined Refrigerator-Freezers HC 2062 HCB 2062 HC/HCB 2062 7084 341-00
Important Please Read and Follow these Instructions Contents Page Unit dimensions.............................................................. 4 Unit Venting..................................................................... 4 Cabinet opening dimensions.......................................... 5 Panel Dimensions - Framed Cabinet Design................ 6 Panel Dimensions - Frameless Cabinet Design............ 7 Mounting the anti - tipping device on concrete floors....
Safety Disposal of Old Appliance DANGER! Risk of child entrapment. Child entrapment and suffocation are not problems of the past. Junked or abandoned refrigerators are still dangerous – even if they will sit for “just a few days.” If you are getting rid of your old refrigerator, please follow these instructions to help prevent accidents. Before you discard old appliances: • Remove the doors.
Planning Information Unit Dimensions Unit Venting - Figure 1 - Figure 3 HC/HCB 20 appliances do not require any ventilation openings in the cabinet. The required airflow is directed through the toe kick area. Figure 1 A = 3" (76 mm) B = 79-13/16" (2027 mm) C = 35-13/16" (910 mm) D = 3" (76 mm) E = 24" (610 mm) G = 42-7/16" (1078 mm) H = 37-1/8" (943 mm) Door swing clearence - Figure 2 Please allow for door swing clearance at locations next to a wall.
Planning Information Cabinet Opening Dimensions Inset cabinet Depth D - Figure 4 Frameless/faceframe cabinet Depth D 24" + panel thickness For appliance with panel to be flush, adjacent cabinetry depth must equal appliance depth (24") plus panel thickness (5/8" - 3/4"). 24" IMPORTANT For 24" cabinets, the water line opening must be in the location as shown. This is where the power cord extends from the back of the appliance.
Planning Information Panel Dimensions - Inset Installation Style Appliance and panels sit fully within the opening and are flush with what could be its own box, between two pantry cabinets or decorative columns, etc. This is the most common installation scenario. - Figure 5 The panels should be at least 5/8 inch (16 mm) thick to allow the connecting rails to be fastened to them. IMPORTANT The maximum panel thickness is 3/4" (19 mm). You can order stainless steel panels for inset installation style.
Planning Information Panel Dimensions - Frameless Installation Style With this installation style, these wider appliance panels partially overlay the shared side gables of adjacent cabinetry so as to mimic the look of a frameless style cabinet. - Figure 6 The gap between panels with frameless installation style is 1/4" (6 mm). The panels should be at least 5/8 inch (16 mm) thick to allow the connecting rails to be fastened to them. IMPORTANT The maximum panel thickness is 3/4" (19 mm).
Blocking for Safety Mounting the anti tipping device on concrete floors - Figure 7 - 8 Secure the appliance in place so it does not tip forward when the fully stocked door is opened. The anti tipping bracket is provided with the appliance. 1. Mark the center line of the appliance on the back wall. Align the anti tipping bracket center to this line. Wall Be sure that there is no plumbing or electrical wiring located in this area which screws or drills could damage. Figure 7 2.
Blocking Mounting the anti tipping device in cabinets deeper than 24" - for Cover strips Safety - Figure 12 Figure 10 - 11 Before connection to the water supply, the cover strips provided must be fitted to the appliance. It is necessary because the appliance will be moved into its recess. To ensure the compressor mounting plate reaches the anti tipping bracket in cabinets deeper than 24", a wooden spacer must be mounted between the appliance back and the wall.
IceMaker Safety Instructions and Warnings Water Connection Adapter • Do not install the water connection while the combined refrigerator-freezer is connected to an electrical outlet. Figure 13 • The connection to the water supply may only be made by a trained and licensed plumber. • All equipment and devices used to supply the water to the appliance must comply with the current regulations for your geographical area.
IceMaker Connection to the Water Supply 1. Move the appliance towards the final position and leave enough space to work behind. WARNING! To prevent the appliance from tipping forward the compressor mounting plate must have contact with the anti tipping bracket (Figure 16). 2. Insert the water supply line into its intended opening at the back of the appliance (Figure 15). 5. Remove the cover from the solenoid valve (Figure 17). 3. Move the power supply line to the area of the electrical outlet.
Installation Leveling the Appliance Fasten the appliance in the recess - Figure 20 - Figure 18 1. Adjust the height of the appliance at the front by twisting the leveling feet (A/F 27). Use the open-ended spanner provided. Fasten the appliance in the recess through the upper and lower hinges of the refrigerator doors. Use 2 screws for each hinge. 1 2. Adjust the height of the appliance at the rear by turning the adjusting . bolts 2 3. Rotate leveling feet until firmly in place against the floor.
Installation Mounting the attachment brackets onto the door panels - Figure 22 Mark lines on the refrigerator door panels as shown in Figure 22. Align the dismounted brackets of the refrigerator doors to the lines on the refrigerator door panels as shown in Figure 22 a. Fasten each bracket with any hole wherever possible using a minimum of 6 screws 4 x 16 mm. Fasten the brackets provided onto the freezer drawer panels using three screws (4 x 16 mm) for each bracket (Figure 22 b).
Installation Mounting the freezer drawer panels - Figure 23 Mounting the refrigerator door panels - Figures 24 - 33 1. Pull out the upper freezer drawer and screw on the panel with three screws at left and right hand side using the screws as shown in Figure 23. The description is for one panel only. The procedure is the same for both panels. 2. Close the drawer and check the position to the surrounding cabinet panels. Align the panel in vertical direction by loosening the screws left and right.
Installation To make it possible to fasten the refrigerator panel at the bottom the soft-stop cylinder must be dismantled. 5. Grasp the soft-stop cylinder and pull down (Figure 26). 7. Dismantle the lower attachment bracket from the refrigerator door. Align the bracket to the lines on the refrigerator door panel. (Figure 28). Fasten the bracket with any hole wherever possible using a minimum of 6 screws 4 x 16 mm. The soft-stop cylinder retracts in the detached state. Figure 28 Figure 26 6.
Installation 10. Move the panel to the left until it makes contact with the center rail (Figure 30). 13. Extend the soft-stop cylinder and connect with the ball stud (Figure 32). 11. Tighten the hex nuts finally. Figure 32 Figure 30 14. Click cover into place (Figure 33). 12. Fasten the refrigerator panel using the same screws that held the lower bracket before removal (Figure 31).
Installation Mounting the ventilation grille - Figure 34, 35 1. Pull out the bottom freezer drawer. 2. Remove the blue protection film from the dust filter provided and insert the filter into its opening in the toe kick area as shown in Figure 34. Attach the filter at the bottom, press down the button and click into place. Figure 34 3. Mount the ventilation grille as shown in Figure 35. IMPORTANT Only use the ventilation grille provided with the appliance.
For Service in the U.S. Liebherr Service Center Toll Free: 1-866-LIEBHER or 1-866-543-2437 Email: Service-appliances.us@liebherr.com PlusOne Solutions, Inc. 3501 Quadrangle Blvd, Suite 120 Orlando, FL 32817 For Service in Canada Liebherr Service Center Toll Free: 1-888-LIEBHER or 1-888-543-2437 www.euro-parts.