Design Guide

Fully Integrated
24" and 48" Models: HF 861 / HRB 1120, SBS 19H1
31
Ventilation through the cabinet base at the bottom can be
achieved by installing the provided ventilation grille (3) or via a
ventilation opening of at least 31 in.² (200 cm²).
When using the provided ventilation grille (3), please proceed
as follows:
- In the cabinet base, cut out a ventilation opening that is 17-
23/32 in. (450 mm) in width and 2-7/32 in. (56 mm) in height.
- Insert ventilation (3) grille into the cabinet base cut-out (1).
- From the back side, slide the snap-fits (2) into the grille until
the hooks make contact with the cabinet base.
- Completely mount cabinet base (with ventilation grille and
snap-fits) to kitchen cabinet.
Kitchen Cabinet Base Grille Location Of The Electrical Outlet
Do not locate the elec-
trical outlet behind the
appliance!
The electrical outlet is re-
quired to be accessible for
installation and service.
Choose the position of the
electrical outlet considering
these specifications.
Free length of the power cord
is 85".
Power cord exits rear of ap-
pliance at this location.