Installation Instructions

Table Of Contents
u
Note the additional space needed (for depth of door
stop components): Allow the hinges and covers
Fig. 23 (16)
to protrude by the additional distance.
All appliances:
u
Adjust the adjustable feet with the supplied open-
ended wrench
Fig. 14 (21)
to align the appliance verti-
cally.
w
The appliance is now positioned correctly depthwise.
The distance between the front edge of the unit side
wall and the appliance itself is 42 mm all around. (Note
the additional space needed for door stop components
such as knobs and sealing lips.)
Note
Malfunction due to incorrect assembly!
If the spacing is not observed, the appliance door may not
seal completely. This can cause icing up, the formation of
condensate, and malfunctions.
u
A continuous space of 1-21/32 '' (42 mm) must be
maintained. (Note the additional space needed for door
stop components such as knobs and sealing lips.)
To secure the appliance in the recess:
u
Screw long chipboard screws
Fig. 27 (22)
at the top and at the
bottom through the hinge plates.
Take care that screws will not
protrude from an exposed end
cabinet wall.
Fig. 27
On the top handle side:
u
Loosen the screws
Fig. 28 (19)
slightly.
u
Secure the top
mounting bracket
Fig. 28 (17)
with a ø4x19
chipboard screw
Fig. 28 (25)
to the unit
wall.
u
Break off the
protruding end of the
cover
Fig. 28 (16)
.
Fig. 28
u
Tighten the screws
Fig. 28 (19)
.
u
Place cover
Fig. 28 (16)
in position.
On the bottom handle side:
u
Loosen the screws
Fig. 29 (19)
slightly.
u
Secure the bottom
mounting bracket
Fig. 29 (17)
with a ø4x19
chipboard screw
Fig. 29 (25)
to the unit
wall.
u
Break off the protruding
end of the cover
Fig. 29 (16)
.
u
Tighten the screws
Fig. 29 (19)
.
u
Place the cover
Fig. 29 (23)
onto the
bottom mounting
bracket
Fig. 29 (17)
.
Fig. 29
u
Slide the equalizer trim
Fig. 20 (11)
toward the handle
side as far as it will go.
u
Close the appliance door.
6.2 Installing the unit door
Fig. 30
u
Check 5/16 '' (8 mm) presetting (distance between
appliance door and lower edge of crosspiece).
u
Raise the fitting aids
Fig. 30 (30)
to the unit door height.
Bottom stop angle ▲of fitting aid = upper edge of the
unit door to be fitted.
u
Unscrew the crosspiece
Fig. 31 (31)
by undoing the
locknuts
Fig. 30 (32)
.
u
Hang the cross-
piece
Fig. 31 (31)
on
the inside of the unit
door using the fitting
aids
Fig. 31 (30)
.
With a 23-5/8 ''
(600 mm) wide
cabinet:
u
To center the cross-
piece
Fig. 31 (31)
:
Mark a short center
line on the unit door
and put the tip of
the arrow on the
crosspiece on it.
Fig. 31
w
Distances to the outer edges are the same to the right
and to the left.
With a 24 '' (609.6 mm) wide cabinet:
Installation
12 * Depending on model and options