Installation Instructions

Table Of Contents
- The upper ventilation cross-section can be set up
directly above the appliance
Fig. 1 (2)
, near the ceiling
above a cabinet
Fig. 1 (3)
, or as an air vent in an inter-
mediate ceiling
Fig. 1 (4)
.
Fig. 2
- An unobstructed air way with a depth of at least
1 1/2 in. (38 mm) must be ensured at the back of the
kitchen cabinet.
u
The air-circulation clearances indicated above must be
maintained.
The ventilation from below through the cabinet floor can
be provided with the supplied ventilation grille
Fig. 3 (3)
or
a ventilation opening of with a cross-sectional area of at
least 31 in
2
(200 cm
2
). If you are using the supplied venti-
lation grille
Fig. 3 (1)
, proceed as follows:
Fig. 3
u
In the cabinet floor, cut a ventilation opening
17 23/32 in. (450 mm) wide and 2 7/32 in. (56 mm)
high.
u
Insert the ventilation grille
Fig. 3 (1)
into the cutout in the
cabinet floor
Fig. 3 (2)
.
u
Slide the snap connectors
Fig. 3 (3)
into the grille from
behind until the hooks touch the cabinet floor.
u
Fit the cabinet floor (with the ventilation grille snapped
into place) into the cabinet.
Kitchen cabinet setup
4 * Depending on model and options