Design Guide

Fully Integrated
HC 1001/HC 1050 - SBS 20H0, HC 1011/HC 1060 - SBS 20H1, HF 851/HRB 1110 - SBS 19H0
Ventilation Requirements
11
This is a fully integrated refrigerator-freezer which means that it
is fully enclosed by a kitchen cabinet. This type of cabinet must
be carefully constructed using the correct dimensions and it
must provide suitable ventilation to ensure proper appliance
operation.
Kitchen Cabinet Airflow
1. The following ventilation dimensions must be observed:
There must be a ventilation space at least 31 in.² (200 cm²)
attheairowinlet(1)andattheairowoutlet(2).
The top ventilation space can be directed in one of the fol-
lowing ways:
A) Directly over the appliance (2) with either an optional fac-
tory air vent or custom made one.
B) Above the cabinet and below the ceiling (3).
C) Through a vent installed in a soffit (4).
A
B
C
A minimum space of 1 1/2" is required when a cabinet is built
above and/or underneath.
B - Side view
Cabinet
Refrigerator