Installation Instructions

Table Of Contents
u
Write the date of the next filter replacement on the
supplied adhesive label
Fig. 40 (9)
and affix it to the
module.
u
Make sure the filter is leak-tight and no water is coming
out.
Note
New water filters may contain particulate matter.
u
Do not consume or use ice cubes produced within 72
hours after replacing the filter.
w
The water filter is now ready for use.
8 Connecting the appliance
WARNING
Electrical shock hazard!
u
Start-up should only take place once the appliance has
been installed according to these instructions.
u
Electrically ground appliance.
u
Do not ground to a gas pipe.
u
Check with a qualified electrician if you are not sure the
appliance is properly grounded.
u
Do not have a fuse in the neutral or grounding circuit.
u
Do not use an extension cord, power bar or a multiple
socket adapter.
u
Do not use a power cord that is frayed or damaged.
WARNING
Electrical shock hazard!
This appliance is equipped with a three-prong (grounding)
polarized plug for your protection against possible shock
hazards. Electrical Grounding Required.
u
Do not remove the round grounding prong from the
plug.
u
Do not use a two-prong grounding adapter.
-
Wait 1 hour after installation before you plug in the
appliance. This allows the refrigerant and system lubri-
cation to reach equilibrium.
-
Make sure incoming voltage is the same as the appli-
ance rating. A 110-120 Volt, 60 Hz, 15 Amp electrical
supply (20 Amp for side-by-side installations) circuit
that is controlled by a circuit breaker or fuse is required.
-
We recommend using a dedicated circuit for this appli-
ance to prevent electrical overload.
-
Follow all Federal, State and local electrical, fire and
building codes and ordinances when installing the
receptacle and / or the appliance.
-
In some communities, a wall switch is required to turn
power to the appliance ON and OFF.
-
To reduce the risk of fire, electric shock, or personal
injury, installation work and electrical wiring must be
done by a qualified electrician in accordance with all
applicable codes and standards, including fire-rated
construction.
-
The socket must be easily accessible so that the appli-
ance can be disconnected from the mains quickly in an
emergency. It must not be behind the back of the appli-
ance.
-
The top of the electric outlet must be located within
82-5/8 in. (2100 mm) from the top of the base in the
cabinet.
Connecting the appliance
15