User Manual

17
Stop End Pipes
Technical Data
Stop end pipes
mm 500 600 800 1000 1200 1500
Wall thickness mm 15 15 15 18 18 20
Length 2.5 m kg 700 841 1149 1595 1926 2552
Length 5.0 m kg 1162 1394 1889 2705 3263 4412
Length 10.0 m
kg
2082 2498 3368 4927 5936 8132
Length 15.0 m kg 3002 3602 4847 7148 8609 11852
Lifting caps*
Length mm 1050 1050 1125 1150 1150 1150
Weight kg 209 251 362 412 454 630
Shoes
Length mm 720 720 720 720 720 720
Weight kg 230 276 368 471 567 710
General Remarks
Stop End Pipes
The tube connections (bayonet fitting) are manu-
factured from high-strength steel and are machined
after rolling. Because of higher quality material and
adequately dimensioned wall thicknesses with addi-
tional stiffenings, the stop end pipes have proven to
be very effective for the construction of diaphragm
walls up to 60 m depth.
The tube connections can easiliy be connected,
they have a radial fit and are interchangeable.
Stop end pipes 1000 m prior to shipment
By means of the uncoupling device which we have
developed as an accessory for our tube extracting
machines, the tube connections can be opened
and closed fully automatically which means that the
time for the installation and removal of the stop end
pipes can be reduced considerably.
*for previous design only