Installation Manual

5
P
lanning
i
nformaTion
This is where the power cord extends from the back of
the appliance.
Free length of the power cord = 90 - 1/2 inch (2300 mm)
Be sure to take these specifications into consideration
when choosing the location of the electrical outlet.
IMPORTANT
The electrical outlet may not be situated behind
the appliance and must be easily accessible.
Installation Dimensions
IMPORTANT
In order to avoid any problems when installing the
appliance and to avoid damage to the appliance:
The kitchen units must be aligned horizontally
and vertically.
Minimum wall thickness of the body of the
unit = 5/8” (16 mm).
Appliance Venting
Important
The area of ventilation
above the unit should be
at least 31 square inches
(200 c).
The air supply passes
below the appliance door.
Types of Air Outlet
1
Directly above the appliance
2
Above the top unit
3
From the front of the top unit with decor grille
IMPORTANT
When using decor grilles, it must be taken into
account that the clear ventilation cross-section
corresponds to the sum of the individual openings in
the grille.
A cut-out section of merely 31 square inches
(200 c) for installing the ventilation grille is thus
not sufficient.