Operation Manual

Fig. 9
- The water pressure has to be be-
tween 0.15 MPa and 0.6 MPa. (1.5
bar- 6 bar)
- The water supply to the appliance
must be via a cold water pipe which
withstands the operating pressure
and complies with the hygiene regu-
lations.
Use the accompanying stainless
steel hose (1.5 m). Do not reuse old
hoses. A 3 m hose is available from
the customer service department and
has to be fitted by an expert.
In the hose connecting piece is a
sieve with seal.
- Between the hose and the domestic
water connection there has to be a
stopcock to interrupt the water supply
in case of need.
- All the fixtures and fittings used for
water supply have to comply with the
applicable regulations of the respec-
tive country.
- Do not damage or kink the water inlet
pipe when installing the appliance.
u
Connect the straight part of the accompanying stainless steel
hose to the stopcock.
The solenoid valve is at the bottom back of the appliance. It has
a metric R3/4 connecting thread.
u
Connect the angled part of the stainless steel hose to the sol-
enoid valve.
u
Open the stopcock of the water supply and check
that the entire water system is leakproof.
Before initial use:
u
Have the water pipe bled of air by the proper ex-
pert.
4.3 Insertion into a row of kitchen units
Fig. 10
(1) Stack cabinet (3) Kitchen cabinet
(2) Appliance (4) Wall
The appliance can be inserted into a row of kitchen units. To
match the appliance
Fig. 10 (2)
to the height of the row of units,
a suitable stack cabinet
Fig. 10 (1)
can be fitted above the appli-
ance.
When inserting the appliance into a row of standard kitchen units
(max. depth 580 mm), the appliance can be installed directly next
to the kitchen unit
Fig. 10 (3)
. The appliance door projects relative
to the front of the kitchen unit by 34 mm at the side and by
50 mm in the middle of the appliance. It can be opened and
closed perfectly as a result.
Important for the ventilation:
-
At the back of the stack cabinet there has to be a ventilation
duct of at least 50 mm depth throughout the width of the stack
cabinet.
-
The ventilation space under the ceiling has to be at least
300 cm
2
.
If the appliance is installed with the hinges next to a wall
Fig. 10 (4)
, the distance between appliance and wall has to be at
least 36 mm. This corresponds to the projection of the handle
when the door is open.
4.4 Transporting the appliance
CAUTION
Risk of injury and danger of damage as a result of incorrect trans-
port!
u
Transport the appliance in a packed condition.
u
Transport the appliance upright.
u
Do not transport the appliance without assistance.
4.5 Installing the appliance
In the event that the appliance is damaged, contact the supplier
immediately before connecting to the mains.
The floor at the site must be flat and level.
Do not install the appliance in a location where it is exposed to
direct radiation of the sun, next to a cooker, heater and similar.
Always install the appliance directly against the wall.
Do not install the appliance without assistance.
Standard EN 378 specifies that the room in which you install your
appliance must have a volume of 1 m
2
per 8 g of R 600a refrig-
erant used in the appliance. If the room in which the appliance is
installed is too small, a flammable gas-air mixture may form in the
event of a leakage in the refrigeration circuit. The quantity of re-
frigerant used in your appliance is indicated on the type plate on
the inside of the appliance.