Manual

12
job site:
machine ID:
start date:
stop time:
start time:
duration:
05.11.2008
12:16:48
12:48:48
00:32:00
16383sz.mt
115507
CFA drilling
pile number:
maximum depth:
total concrete vol.:
concrete volume pile:
overconsumption:
maximum incline:
E02
2227 cm
15,123 m³
14,531 m³
29,8 %
0,4 °
time
12:4512:4012:3512:3012:2512:20
depth [cm]
2.200
2.000
1.800
1.600
1.400
1.200
1.000
800
600
400
200
0
conc. press. [bar]
5
4,5
4
3,5
3
2,5
2
1,5
1
0,5
0
depth [m]
20
15
10
5
0
drill press. [bar] v
3002001000
crow d force [kN] v
10
drill progr. [r/m] v
1086420
crow d speed [m /min] v
43210
rev. speed [r/min] v
2520151050
depth [m]
20
15
10
5
0
pile radius [cm]
6040200204060
conc. press. [bar] ^
543210
crow d speed [m /min] ^
210
rev. speed [r/min] ^
10
Electronic Evaluation
Quality assurance through process data recording (PDE)
The process data is constantly measured during the working process. External sensors can also be connected
to the system. Measurement data relevant to the working process is displayed on the monitor in the cabin. The
operator can then control all processes and, if necessary, correct them. The data is stored by the system and can
be transferred to a computer using a CompactFlash-Card.
Evaluation and visualisation through process data reporting (PDR)
The Liebherr software for process data reporting allows to further process the data on a PC, where they are directly
stored, sorted and visualised. Thus, customer-specific evaluations can easily and quickly be created.