Assembly and installation instructions

WARNING
Electrical shock hazard!
This appliance is equipped with a three-prong (grounding)
polarized plug for your protection against possible shock
hazards. Electrical Grounding Required.
u
Do not remove the round grounding prong from the
plug.
u
Use only an grounded adapter.
-
Wait 1 hour after installation before you plug in the
appliance. This allows the refrigerant and system lubri-
cation to reach equilibrium.
-
Make sure incoming voltage is the same as the appli-
ance rating. A 110-120 Volt, 60 Hz, 15 Amp electrical
supply (20 Amp for side-by-side installations) circuit
that is controlled by a circuit breaker or fuse is required.
-
We recommend using a dedicated circuit for this appli-
ance to prevent electrical overload.
-
Follow all Federal, State and local electrical, fire and
building codes and ordinances when installing the
receptacle and / or the appliance.
-
In some communities, a wall switch is required to turn
power to the appliance ON and OFF.
-
To reduce the risk of fire, electric shock, or personal
injury, installation work and electrical wiring must be
done by a qualified electrician in accordance with all
applicable codes and standards, including fire-rated
construction.
-
The Power Plug must be easily accessible so that the
appliance can be disconnected from the mains quickly
in an emergency. It must not be behind the back of the
appliance.
-
The top of the electric outlet must be located within
82-5/8 in. (2100 mm) from the top of the base in the
cabinet.
Connecting the appliance
14 * Depending on model and options