Assembly and installation instructions

NOTICE
An excessively heavy unit door can cause potential
damage!
If the unit door is too heavy, we cannot rule out damage to
the hinges, which may compromise the use of the unit.
u
Before installing the unit door, ensure the door does not
exceed the permissible weight.
Appliance type Maximum weight of
unit door
UR 500 / UF 501 / UB 501 22 lbs (10 kg)
7 Reversing the door
WARNING
Risk of bodily injury due to the door falling off.
If the fasteners are not installed with the proper torque, the
door may fall off. In addition, the door may not close, thus
impairing the cooling performance of the appliance.
u
Tightly secure the hinges along ball stud of the soft
stop mechanism by applying a torque of 3 lb-ft (4 Nm).
u
Tighten the soft stop mechanism retainer firmly with
2.5 lb-ft (3 Nm).
u
Check all screws and retighten if necessary.
Note
The door stop can only be changed if there is sufficient
space above to remove the hinge fixing bracket and fit it
on the opposite side again. This is not normally the case
when installing in a recess.
u
Change the door stop before the appliance is installed
in the recess.
There is the risk of injury when doing this. Obey
the safety instructions.
The instructions apply to several models. Only
perform this step if it applies to your appliance.
Select one of the alternatives shown.
Only undo the screw. Don't take it out.
Check the screws and if necessary tighten them.
Required tool:
Fig. 3
Fig. 4
CAUTION
Risk of injury if soft stop contracts!
u
Carefully remove soft stop damper.
u
Removing the soft stop damper: Remove the soft stop
damper from the ball stud (1). Unscrew the retainer (2).
Remove the ball stud with a screwdriver (3).
Reversing the door
* Depending on model and options 5