Design Guide

12
a: kitchen cabinet door
b: appliance ventilation grille
c: toe kick panel
d: Air flow
The kitchen cabinet door, the appliance ventilation grille
and the toe kick panel must maintain a minimum opening
of 1-3/8 " (35 mm) to allow proper air flow for ventilation.
Case E:
The ventilation openings in the ventilation grille are freely
visible or are scarcely covered by the unit door.
• Ventilationissufficient
• Theventilationgrillecanbepulledforwardasfaras
possible so that the front edge of the ventilation grille
and the toe kick panel lie flush.
Case F:
The kitchen cabinet door covers the ventilation openings
of the appliance ventilation grille b and part of the toe
kick panel.
• Toguaranteesufficientventilation,theremustbeaven-
tilation gap of 1-3/8 " (35 mm) behind the unit door.
•Pushtheventilationgrillefullyback.
After installing the kitchen cabinet door, there must be a
ventilation gap between the appliance ventilation grill and
the kitchen cabinet door. The ventilation grille is movable
to guarantee sufficient ventilation.
Important
A minimum opening of 1-3/8" (35 mm) must be
maintained to allow proper air flow for ventilation.
Ventilation Requirements
This is a fully integrated undercounter model which
means that it is fully enclosed by a kitchen cabinet. This
type of cabinet must be carefully constructed using the
correct dimensions and it must provide suitable ventila-
tion to ensure proper appliance operation.
IMPORTANT
To ensure proper refrigeration performance of
the appliance, designed ventilation is required.
The ventilation grille
must be installed
onto the appliance.
The foam block supplied
must be installed in order to ensure
the required air flow through the
appliance base.
Failure to follow
this instruction
may result in poor
refrigeration perfor-
mance.