4 MAIN WALL CONTROLS
Digital Wall Control (99-DXPL02)
Operating Instructions (cont.):
Setting the Mode of Operation:
There are 5 modes of operation available with this control. Press the Mode Button to cycle through the
different modes of operation:
Continuous Ventilation
20 min. Ventilation / 40 min. Recirculation
20 min. Ventilation / 40 min. OFF
10 min. Ventilation / 50 min. OFF
Continuous Recirculation
Setting the Dehumidistat:
Press the Dehumidistat Button to adjust the Dehumidistat set point. The Dehumidistat can be set between
20% RH and 60% RH. The digital wall control displays the current indoor humidity in LARGE numbers and the
Dehumdidstat setting in SMALL numbers on the screen. If the indoor humidity is above the set point, the
digital wall control will initiate HIGH Fan speed operation in Ventilation mode until the indoor humidity has
been reduced below the set point.
Reset Button:
The RESET Button will clear the current Fan, Timer, Mode, and Dehumidistat settings set the unit into LOW fan
speed, Ventilation Mode, and set the Dehumidistat set point to 40% RH.
Service Indicator:
A service indicator appears when the unit requires routine maintenance. Refer to Maintenance Instruction
.
Press and hold the ON/OFF button for 5 seconds to reset the service indicator after routine maintenance
has been performed.