User Guide

Table Of Contents
14
Optional Lifebreath Ventilation Control - Part #99-BC02
Key Features:
2 speed fan setting (LOW / HIGH)
Standby setting (fan OFF)
Electronic Dehumidistat
Compatible with 99-DET02 Wireless Timers
Slim-line design
Connect to 3 wire 20 gauge low voltage
wire
Setting the Ventilation Speed
Press and release the Fan button to select LOW or HIGH fan speed. The corresponding “Indicator Light" will illumi-
nate. If both LO and HI indicator lights are off, the fan is OFF but will turn ON if required by the Dehumidistat or remote
Timer (if installed).
Humidity Control
Your unit will reduce indoor humidity when outdoor humidity levels are lower than indoor humidity levels. This feature is
only effective when the outdoor temperature is below 59˚F (15˚C).
Setting the Dehumidistat
Press and release the Dehumidistat button until the Dehumidistat Light is at the desired setting. After a few seconds
the Dehumidistat light will either flash or be on continuous.
A flashing light indicates the humidity level is higher than the setting and the unit is operating on high speed ventilation.
A continuous light indicates the humidity level is lower than the setting. Refer to the unit's Home Owner’s manual for
instructions on how the Dehumidistat works.
The Dehumidistat will override the current speed setting to HIGH speed.
The Dehumidistat function can be turned OFF by pressing the button until no Dehumidistat light is on.
Note - Only 1 Dehumidistat should be installed in a system.
Humidity
Setting
ON/OFF
Button
Fan Speed
Indicator
Fan
Speed
Dehumidi-
stat Button
ON/OFF
BC02 Operating Instructions:
Turning on the Control
Press and release the ON/OFF button . The light
above will illuminate.
Optional Lifebreath 3 Speed Control - Part #99-500
Key Features:
3 Speed Fan setting (LOW / MEDIUM / HIGH)
4 wire; 20 gauge wire (minimum)
Connect to Red, White, Yellow, Green.
When used in conjunction with the 99-BC02,
the BC02 control must be ON for the 99-500
control to operate. The 99-BC02 will override
the 99-500 control when the Dehumidistat is
operating or the control is set to HIGH speed.
ATTENTION
!
Indicator