User Guide

Table Of Contents
15
Optional Lifebreath Dehumidistat - Part #99-DH01
Key Features:
The Dehumidistat measures the indoor humidity
level and will initiate high speed ventilation when
the moisture level in the building exceeds the set
point on the control.
Once the humidity in the building is reduced, the
HRV will revert back to its previous setting.
The Dehumidistat should be set to OFF for all sea-
son except the heating season.
Connect to 3 wire 20 gauge low voltage wire.
Humidity Control
Your HRV will produce a dehumidifying effect when
outdoor humidity levels are lower than indoor humidity
levels. Never use the Dehumidistat feature when out-
door temperatures are above 59 F (15 C).
Note: The indoor humidity level is measured at the
control.
Setting the Dehumidistat
Press and release the Dehumidistat button until the
Dehumidistat Light is at the desired setting. After 5
seconds the Dehumidistat light will either flash or be on
continuous.
A flashing light indicates the humidity level is higher
than the setting and the unit is operating on high
speed ventilation. A continuous light indicates the hu-
midity level is lower than the setting. Refer to the unit's
Operation & Installation Manual for instructions on how
the Dehumidistat works.
Note - Only 1 Dehumidistat should be active on a sys-
tem.
Instruction Card
Dehumidistat
Adjust Button
Dehumidistat Indicator LEDs
Set to the desired humidity lev-
el. High speed ventilation will
initiate when the indoor mois-
ture level exceeds the set point
on the control.