User Guide

Table Of Contents
16
Optional Lifebreath Wireless Timer - Part #99-DET02
Note
The wireless Timers and Repeaters must be matched to the
main wall control of the HRV / ERV. This process is called
"Pairing". Multiple Timers and Repeaters can be paired to a
single wall control.
Pairing:
1. Turn on the main wall control by pressing the ON/
OFF button and remove the battery from Timer.
2. Press the left and right buttons simultaneously on
the main wall control ( and ). The bottom row
of 3 LED's will begin flashing. This indicates that the
main control is now in pairing mode. (Figure E)
3. Keep the Timer within 16” of the main wall control
when pairing.
4. Install the battery in the DET02 Timer. All four
lights on the Timer will immediately flash 5 times,
then only the red battery light will remain on for
approximately 12 seconds after which the "40" light
flashes the rev code. 20, 40, 60 lights will flash until
paired or will stop if not paired within 12 seconds.
If pairing was not successful you now must return
to step 1 to restart the pairing process.
5. Press the button on the main wall control to
exit.
To pair additional DET02 Timers with the same wall
control, or if pairing was not successful, repeat steps 1-
6.
When paired, the DET02 Timers can be moved and in-
stalled elsewhere. Estimated range of the Timer is 40
with no obstructions. A RX02 Repeater may be installed
to increase the range of the Timers.
Test if pairing was successful by pressing the Select
Button and listen for the HRV / ERV to initiate HIGH fan
speed Ventilation.
Un-pairing:
1. Remove the battery from the back of the DET02
Time.
2. 2. Press and hold the Select Button on the front of
the Timer.
3. While holding the Select Button, reinsert the battery
in the Timer. Continue holding the select button
until the LED under "40" begins flashing. The
DET02 Timer will now be unpaired with the main
wall control.
The Timers may be installed onto a flush mounted electri-
cal switch box or it may be surface mounted onto a wall.
Multiple Timers may be installed in a ventilation system.
To increase the range of a wireless Timer, a RX02 Repeat-
er should be used.
Figure A
Figure B
Figure C
Figure D
Figure E
1/8 in hole for
screw and
anchor
1/8 in hole for
screw and
anchor
1/8 in hole for
screw and anchor
1/8 in hole
for screw
and anchor
Face Plate
Back Plate
Break off tab
Break off tab
Alternate Wall Mount
BC02
Control
DET02 Timer
Removable
Back Plate
20/40/60 minute
status lights
Select Button
initiates high
speed ventilation
for 20, 40 or 60
min.
Battery Indicator
Press simultaneously to
initiate pairing mode
NOTE: Your
control may
look different
than the one
shown.