Optional Lifebreath Wireless Repeater - Part #99-RX02
The RX02 Repeaters are to be plugged directly into a 120V power outlet
1. Turn on the main wall control by pressing the ON/OFF button .
2. Press the left and right buttons simultaneously on the main wall control ( and ). The bottom row of 3
LED's will begin flashing. This indicates that the main control is now in pairing mode.
3. The RX02 Repeater must be powered within 16” of the main wall control for pairing. If an outlet is not
available an extension cord should be used to power the repeater initially for pairing.
4. Plug the RX02 Repeater into the power outlet. The green light will flash after approximately 12 seconds
indicating that the repeater is paired with the main wall control.
5. Press the ON/OFF button on the main wall control to exit pairing mode and the Repeater may now be un-
plugged and moved to its permanent location.
To pair additional RX02 Repeaters with the same wall control, repeat steps 1-5 until
all Repeaters have been paired.
When installed in its permanent location, the green LED will remain solid to indicate
the best location and the Repeater can be moved farther if required. The green LED
will flash to indicate it is in a good location. A red light indicates the Repeater is out of
range and needs to be moved closer to the main wall control.
RX02
Repeater
Power
Plug
Optional Lifebreath 20/40/60 Minute Timer - Part #99-DET01
Operating the Timer
Press and release the Select Button to activate a 20, 40
or 60 minute HIGH speed override cycle. The Light will
illuminate and the unit will run on HIGH speed Ventila-
tion for the selected time. The Light will dim after 10
sec. for run time. The Light will flash during the last 5
min. of the cycle. The Timer connected to the unit will
illuminate for the duration of the override when the Se-
lect Button is pressed.
Lockout Mode
Lockout Mode is useful if you wish to disable the Tim-
ers. The Timer can be set to lockout mode by pressing
and holding the Select Button for five seconds. After 5
sec., the Light will flash; release the Select Button. The
Timer is now in lockout mode. If the Select Button is
pressed during lockout mode the Light will momentarily
illuminate but no override will be initiated.
If lockout mode is initiated when the Timer is activated,
the Timer will continue its timed sequence but will not
allow any further overrides to be initiated. Lockout
mode can be unlocked by pressing and holding the Se-
lect Button for 5 sec. After 5 sec. the Light will stop
flashing. Release the Select Button and the Timer will
now operate normally.
Yellow
Red
Green
Status
Lights
Select Button initiates
high speed Ventilation
for 20, 40 or 60 min.
Timers mount in standard 2” x 4” electrical boxes.
Wire multiple timers individually back to the unit.
Use 3/20 low voltage wire
NOTE
YEL RED GRN
DET
Digital Controls
Terminal strip on
Aircom circuit board
Yellow to YEL
Red to RED
Green to GRN
Use 3/20 wire