Install Instructions

14
Optional Lifebreath Wireless Timer - Part #99-DET02
ATTENTION
The Wireless Timers and Repeaters must be
matched to the main wall control of the HRV.
This process is called "Pairing". Multiple
Timers and Repeaters can be paired to a single
wall control.
BC02, BC03 or
BC04 Control
NOTE: Your BC
control may look
different than the
one shown.
Press Simultaneously to
Initiate Pairing Mode
Figure A
Figure B
1/8 in hole for
screw and
anchor
1/8 in hole
for screw and
anchor
Break off tab
Alternate Wall Mount
1/8 in hole for
screw and anchor
Figure C
Back Plate
Face Plate
1/8 in
hole for
screw and
anchor
Break off tab
Figure
E
Figure D
DET02 Timer
20/40/60 Minute
Status Lights
Select Button
initiates high speed
ventilation for 20, 40
or 60 min.
Battery Indicator
Removable
Backplate
The timer will override the operational mode
(regardless of the settings) and initiate HIGH speed
Ventilation. Upon completion of the timer cycle, the HRV
will return to your selected operational mode and speed
setting.
Initiates HIGH speed ventilation for 20, 40 or 60 minutes. The
20/40/60 minute Status Lights indicate HIGH speed
operation.
The Wireless Timers are to be surface mounted onto a
wall. Multiple Wireless Timers may be installed in a ventilation
system. To increase the range of a Wireless Timer, a RX02
Repeater should be used.
Pairing:
To pair additional DET02 Timers with the same wall control, or if pairing
was not successful, repeat steps 1-6.
When paired, the DET02 Timers can be moved and installed elsewhere.
Estimated range of the Timer is 40’ with no obstructions. A RX02 Repeater may
be installed to increase the range of the Timers.
Test if pairing was successful by pressing the Select Button and listen for the
HRV to initiate HIGH fan speed Ventilation.
Un-pairing:
1. Remove the battery from the back of the DET02 Timer
2. Press and hold the Select Button on the front of the Timer
3. While holding the Select Button, reinsert the battery in the Timer. Continue holding the Select
Button until the LED under "40" begins flashing. The DET02 Timer will now be unpaired with the
main wall control.
1. Turn on the main wall control by pressing the ON/OFF
button and remove the battery from Timer.
2.
DET02 with DXPL02 Controls:
Press the left and
right buttons simultaneously on the main wall control
( and RESET buttons). The screen will go blank and
the wireless symbol will appear flashing on the
bottom right of the display. This indicates that the main
control is now in pairing mode. (Figure D)
3.
DET02 with BC02, BC03 and BC04 Controls:
Press the left and right buttons simultaneously on the
main wall control ( and either or buttons,
depending on the main control). The bottom row of 3
LED's will begin flashing. This indicates that the main
control is now in pairing mode.(Figure E)
4. Keep the Timer within 16” of the main wall control when
pairing.
5. Install the battery in the DET02 Timer. All four lights on
the Timer will immediately flash 5 times, then only the
red battery light will remain on for approximately 12
seconds after which the "40" light flashes the rev code.
20, 40, 60 lights will flash until paired or will stop if not
paired within 12 seconds. If pairing was not successful
you now must return to step 1 to restart the pairing
process.
6. Press the button on the main wall control to exit
pairing mode when Timers have been successfully
paired.