Indoor Air Systems Air Conditioner User Manual

12
Model 200ERVD
®
CLEAN • FRESH • AIR
ENGINEERING DATA
LATENT RECOVERY/MOISTURE TRANSFER CORE
The cross-flow energy recovery core transfers heat and water vapour
between the two airstreams. It is easily removed for cleaning or service.
MOTORS AND BLOWERS
- Each air stream has one centrifugal
blower driven by a common PSC motor. 5 speed fan operation.
High speed - 120 VAC, 182 Watts.
FILTERS
- Washable air filters in exhaust and supply air streams.
MOUNTING THE ERV
- Four threaded inserts at corners of case
designed to accept four PVC reinforced polyester straps that are
supplied with the unit.
DEFROST
- Damper defrost system.
CASE
- Twenty gauge prepainted galvanized steel (G60) for superior
corrosion resistance. Insulated to prevent exterior condensation.
DRAIN CONNECTIONS
- Two - 1/2” (12mm) O.D.
CONTROLS
- ControlAir 15
WEIGHT 63 lbs. (28.7 kg) SHIPPING WEIGHT 65 lbs. (29.6 kg)
STALE AIR
TO OUTSIDE
STALE AIR
FROM HOUSE
FRESH AIR
TO INSIDE
14
3
/4"
(375)
19"
(483)
DIMENSIONS 200ERVD
inches (mm)
*
All Duct Connections 6"(150mm)
FILTERS
BLOWERS
*NOTE: Front clearance 
of 25 inches (635 mm) 
is recommended 
for servicing unit.
MOTOR
31"
(787)
FRESH AIR
FROM OUTSIDE
DAMPER
DEFROST
PORT
CONDENSATE DRAINS
ENTHALPIC
CORE
OPTIONS
99-104 Digital Electronic Timer - 20/40/60 min. (3 wire)
99-105 Deluxe Programmable Control includes
Programmable Time Clock, Dehumidistat
and Air Sentry™
99-109 Air Sentry™ Air Quality Monitor designed to accept
remotely mounted Control Pad.
99-186 Weatherhoods, Two - 6” (150mm)
c/w 1/4” (6mm) mesh screen
WARRANTY
Units carry a 5 year warranty on the energy recovery core and
replacement parts.
All units conform to CSA and UL standards.
ERVs are not recommended for regions where the
design temperature is below 25°F (-4°C)
TI-200ERVD
0105
DATE: __________________________
PROJECT: __________________________________________
MECHANICAL CONTRACTOR: _____________________________
511 McCormick Blvd.
London, Ontario
N5W 4C8
Ph: (519) 457-1904
Fx: (519) 457-1676
Email: nutech@lifebreath.com
Website: www.lifebreath.com
PERFORMANCE
Net supply airflow in cfm (L/s) against external static pressure
E.S.P cfm L/s
@ 0.1” (25 Pa) 214 (101)
@ 0.2” (50 Pa) 206 (97)
@ 0.3” (75 Pa) 193 (91)
@ 0.4” (100 Pa) 184 (87)
@ 0.5” (125 Pa) 170 (80)
Sensible Effectiveness
@127cfm (60 L/s)
(CSA C439M)
67%
Sensible Efficiency 32°F (0°C) 60%
Total Efficiency 55%
VAC @ 60HZ 120
WATTS / Low speed 70