Submittal Sheet

Sensible Efficiency: Thermal
Effectiveness: Based on temperature differenal between
the 2 airstreams
Efficiency: Takes into account all power inputs
RNC5-TPD
HEAT RECOVERY VENTILATOR
All units conform to CS A and UL standards
ENGINEERING DATA
THERMALLY CONDUCTIVE, PATENTED ALUMINUM CORE
The cross-flow heat recovery core transfers heat between the two airstreams. It is easily removed for
cleaning or service.
MOTORS AND BLOWERS
Each airstream has an independent motorized impeller with multiple fan speed operations.
FILTERS
Washable air filters in exhaust and supply airstreams.
MOUNTING THE HRV
Threaded inserts at corners of the cabinet designed to accept the “S” hooks and hanging straps supplied
with the unit.
DEFROST
Recirculating damper defrost system.
CASE
20 gauge prepainted galvanized steel for superior corrosion resistance, insulated to prevent exterior
condensation. Drain connections: Two 1/2 in (12 mm) OD.
Balancing ports are located on unit.
INSTALLER SELECTABLE HIGH SPEED SETTINGS
Adjustable DIP switches are located on the circuit board, Hi3 is the factory setting.
Refer to the Installation manual for the adjustment instructions.
ELECTRONICS
The optional controls can be wall mounted in a central location of the home. 3 wire 20 gauge (min.) 100
ft length (max.).
CONTROL OPTIONS
WEIGHT 51 lbs (23 kg) SHIPPING WEIGHT 54 lbs (25 kg)
Units carry a lifeme warranty on the HRV core and
a 5 year replacement parts warranty.
_
_
_
_
_
_
_
_
_
Date:
Tag: Qty:
Project:
Engineer:
Contractor:
Supplier:
Quote #:
Submitted By:
Airflow (cfm)
20
40
60
80
100
120
140
0
0
0.1 0.2 0.3 0.4 0.5 0.6
1
2
160
Static Pressure (in w.g.)
0.7 0.8
180
0.9 1.0 1.1
3
Low
NOTE: All specificaons are subject to change without noce.
17 1/4 in (438 mm)
22 3/4 in (578 mm)
14 in (356 mm)
Front View
Top View
Fresh
Outside
Stale
Air To
Outside
Fresh
Air From
Air To
Inside
Stale
Air From
Inside
Condensate Drains
Motorized
Impeller
Removable
Heat
Recovery Core
Recirculating
Defrost Damper
(For TPD Model
Only)
Filter
Note: Front clearance of 25 in (635 mm)
is recommended for servicing unit. All
ducts use 5 in (125 mm) oval collars,
balancing dampers are located on all
collars.
DIMENSIONS RNC5-TPD
ACCESSORY OPTIONS
99-163 Duct Heater w/Electronic SCR Thermostat - 1 kW, 6 in (152 mm)
99-185 Weatherhoods - Two 5 in (127 mm)
99-190 Dual Hood - One 6 in (152 mm) opening for supply and exhaust.
TIMER OPTIONS
99-DET01 Lifebreath 20/40/60 Minute Timer - Initiates High speed Ventilation for 20, 40 or 60 minutes.
99-BC03 Lifebreath Ventilation Control
Continuous Low fan speed
Humidity control through adjustable
Dehumidistat
3 modes of operation: Ventilation,
Recirculation, 20/40
Compatible with 99-DET02 Wireless Timers
3 wire connection
99-DXPL02 Lifebreath Digital Control
5 speed operation on each mode
Humidity control through adjustable
Dehumidistat
5 user selectable operational modes: Continuous
Ventilation, Continuous Recirculation, 20 ON/40
OFF, 10 ON/50 OFF, 20 ON/40 Recirculation
20/40/60 min. High speed override button
Compatible with 99-DET02 Wireless Timers
3 wire connection
99-BC02 Lifebreath Ventilation Control
2 speed fan setting (Low/High)
Humidity control through adjustable
Dehumidistat
Compatible with 99-DET02 Wireless Timers
3 wire connection
between timer and main wall control if timer is out of range.
99-BC04 Lifebreath Ventilation Control
2 speed fan setting (Low/High)
2 modes of operation: Ventilation, 20/40
Compatible with 99-DET02 Wireless
Timers
3 wire connection
99-DH01 Lifebreath Dehumidistat
Humidity control through adjustable
Dehumidistat
3 wire connection
3 wire connecon.
99-DET02 Lifebreath WIRELESS 20/40/60 Minute Timer - Initiates High speed Ventilation for 20, 40 or 60
minutes. Wirelessly connects to main control for ease of install ation. 40' approximate range.
99-RX02 Lifebreath WIRELESS Repeater - Used to extend range of 99-DET02 Wireless Timers. Plugs into
120V power outlet. Wirelessly connects to main control and 99-DET02. Install at halfway point
Performance
(H V I c e rfie d)
Net supply airflow in cfm (L /s) against external stac pressure
@ 0.1 in (25 Pa) 169 cfm (80 L/s)
@ 0.2 in (50 Pa) 156 cfm (73 L/s)
@ 0.3 in (75 Pa) 149 cfm ( 70 L/s)
@ 0.4 in (100 Pa) 136 cfm (64 L/s)
@ 0.5 in (125 Pa) 126 cfm (59 L/s)
@ 0.6 in (150 Pa) 116 cfm (54 L/s)
@ 0.7 in (175 Pa) 103 cfm (48 L/s)
@ 0.8 in (200 Pa) 89 cfm (42 L/s)
@ 0.9 in (225 Pa) 77 cfm (36 L/s)
@ 1.0 in (250 Pa) 58 cfm (27 L/s)
Max. Temperature Recovery
78%
Sensible Eecveness
@ 66 cfm (31 L/s)
32°F (0°C ) 74%
Sensible Eciency
@ 66 cfm (31 L/s)
32°F (
0°C ) 61%
Sensible Eciency
@ 76 cfm (36 L/s)
-13°F (-25°C )
61%
VAC @ 60Hz 120
Was / L ow speed.
69
Was / High speed 147
Amp rang
1.2
External Stac Pressure Airflow