Submittal Sheet
RNC5-TPF
HEAT RECOVERY VENTILATOR
ENGINEERING DATA
THERMALLY CONDUCTIVE, PATENTED ALUMINUM CORE
The cross-flow heat recovery core transfers heat between the two airstreams. It is easily removed for
cleaning or service.
MOTORS AND BLOWERS
Each airstream has an independent motorized impeller, with multiple fan speed operations.
FILTERS
Washable air filters in exhaust and supply airstreams.
MOUNTING THE HRV
Threaded inserts at corners of the cabinet designed to accept the “S” hooks and hanging straps supplied
with the unit.
DEFROST
Supply air motor switches off and exhaust motor switches to high speed to defrost core.
CASE
20 gauge prepainted galvanized steel for superior corrosion resistance, insulated to
prevent exterior condensation. Drain connections: Two 1/2 in (12 mm) OD.
Balancing ports are located on unit.
INSTALLER SELECTABLE HIGH SPEED SETTINGS
Adjustable DIP switches are located on the circuit board, Hi3 is the factory setting.
Refer to the Installation manual for the adjustment instructions.
ELECTRONICS
The optional controls can be wall mounted in a central location of the home. 3 wire 20 gauge (min.) 100
ft length (max.).
CONTROL OPTIONS
All units conform to C S A and UL standards
(H V I c e rtifie d )
Net supply airflow in cfm (L /s ) agains t externa l s tatic pres s ure
@ 0.1 (25 P a )
@ 0.2 (50 P a )
@ 0.3 (75 P a )
@ 0.4 (100 P a)
@ 0.5 (125 P a)
@ 0.6 (150 P a)
@ 0.7 (175 P a)
@ 0.8 (200 P a)
@ 0.9 (225 P a)
@ 1.0 (250 P a)
Max. T emperature R ecovery
Sens ible Effectivenes s
@ 66 cfm (31 L /s)
32°F (0°C )
Sens ible Efficiency
@ 66 cfm (31 L /s ) 32°F (0°C )
Sens ible Efficiency
@ 76 cfm (36 L /s ) -13°F (-25°C )
120
69
147
1.2
Performance
174 cfm (82 L/s)
165 cfm (77 L/s)
154 cfm (73 L/s)
143 cfm (67 L/s)
132 cfm (62 L/s)
120 cfm (56 L/s)
107 cfm (51 L/s)
95 cfm (45 L/s)
83 cfm (39 L/s)
71 cfm (33 L/s)
79%
75%
66%
56%
External Stac Pressure Airflow
in
in
in
in
in
in
in
in
in
in
VA C @ 60H z
Was / L ow s peed
Was / H ig h s peed
Amp rating
Sensible Efficiency: Thermal
Effecveness: Based on temperature differenal between
the 2 airstreams
Efficiency: Takes into account all power inputs
Airflow (cfm)
20
40
60
80
100
120
140
0
0
0.1 0.2 0.3 0.4 0.5 0.6
1
2
160
Static
Pressure (in w.
g.
)
0.7 0.8
180
0.9 1.0 1.1
3
Low
200
Units carry a lifeme warranty on the HRV core and
a 5 year replacement parts warranty.
_
_
_
_
_
_
_
_
_
Date:
Tag: Qty:
Project:
Engineer:
Contractor:
Supplier:
Quote #:
Submied By:
NOTE: All specificaons are subject to change without noce.
17 1/4 in (438 mm)
22 3/4 in (578 mm)
14 in (356 mm)
Front View
Top View
Fresh
Outside
Stale
Air To
Outside
Fresh
Air From
Air To
Inside
Stale
Air From
Inside
Condensate Drains
Motorized
Impeller
Removable
Heat
Recovery Core
Recirculating
Defrost Damper
(For TPD Model
Only)
Filter
Note: Front clearance of 25 in (635 mm)
is recommended for servicing unit. All
ducts use 5 in (125 mm) oval collars,
balancing dampers are located on all
collars.
ACCESSORY OPTIONS
99-163 Duct Heater w/Electronic SCR Thermostat - 1 kW, 6 in (152 mm)
99-185 Weatherhoods - Two 5 in (127 mm)
99-190 Dual Hood - One 6 in (152 mm) opening for supply and exhaust.
DIMENSIONS RNC5-TPF
WEIGHT 51 lbs (23 kg) SHIPPING WEIGHT 54 lbs (25 kg)
TIMER OPTIONS
99-DET01 Lifebreath 20/40/60 Minute Timer - Initiates High speed Ventilation for 20, 40 or 60 minutes.
99-BC03 Lifebreath Ventilation Control
•
•
•
Continuous Low fan speed
Humidity control through adjustable
Dehumidistat
3 modes of operation: Ventilation,
Recirculation, 20/40
• Compatible with 99-DET02 Wireless Timers
• 3 wire connection
99-DXPL02 Lifebreath Digital Control
• 5 speed operation on each mode
• Humidity control through adjustable
Dehumidistat
• 5 user selectable operational modes: Continuous
Ventilation, Continuous Recirculation, 20 ON/40
OFF, 10 ON/50 OFF, 20 ON/40 Recirculation
• 20/40/60 min. High speed override button
• Compatible with 99-DET02 Wireless Timers
• 3 wire connection
99-BC02 Lifebreath Ventilation Control
• 2 speed fan setting (Low/High)
• Humidity control through adjustable
Dehumidistat
• Compatible with 99-DET02 Wireless Timers
• 3 wire connection
between timer and main wall control if timer is out of range.
99-BC0 4 Lifebreath Ventilation Control
• 2 speed fan setting (Low/High)
• 2 modes of operation: Ventilation, 20/40
• Compatible with 99-DET02 Wireless
Timers
• 3 wire connection
99-DH01 Life breath Dehumidistat
• Humidity control through adjustable
Dehumidistat
• 3 wire connection
3 wire connecon.
99-DET02 Lifebreath WIRELESS 20/40/60 Minute Timer - Initiates High speed Ventilation for 20, 40 or 60
minutes. Wirelessly connects to main control for ease of install ation. 40' approximate range.
99-RX02 Lifebreath WIRELESS Repeater - Used to extend range of 99-DET02 Wireless Timers. Plugs into
120V power outlet. Wirelessly connects to main control and 99-DET02. Install at halfway point