INSTRUCTIONS Instructional Videos Available on our web site: www.lifegardaquatics.
LIFEGARD ALL-IN-ONE FILTER SYSTEM INSTRUCTIONS 24 R442001 All-In-One Single Up To 1000 Gallons R442002 All-In-One Double Up To 1500 Gallons R442003 All-In-One Triple Up To 2000 Gallons All In One Setup Positions for Single, Double and Triple Instructional Videos Available on our web site: www.lifegardaquatics.com Item Part No. Item Part No.
The ALL IN ONE FILTER SYSTEM is a compact filter for ponds, water gardens and fountains easy to install and designed for easy maintenance. Besides offering 2 different fountain spray patterns, it performs three different filtering functions: 1. Multi Layer MECHANICAL Filtration to remove solids. 2. BIOLOGICAL Filtration to promote beneficial bacterial growth. 3. ULTRAVIOLET STERILIZATION puts out 13 Watts of intense UV light to kill free floating algae.
Step – 2: Once all the parts are inspected for correct positioning make sure that the pump cable is running through the locks and is locked in place with the Rubber Cord Grommet (Item # 20) (as seen in Fig. 2A). Step – 3: Correctly place the layer (s) back on the base by sliding the Locking notches into the Notch Holders. Similarly place the Top Housing Cover and Lock it in with the Locking Assembly.
and push the pump into the grove until you hear a locking clock sound. Similarly push in the opposite direction to take the pump out of the grove. Fig. 5 Vertical pull may result in damaging the base or the pump. With the pump out remove the grey pump volute by twisting it counter clockwise. This will expose the impeller and shaft of the pump. Inspect all parts for any debris. Use a brush to remove any debris.
Fig. 8 Step – 7: Adjust the UV Chamber housing and Align the holes for the locking screws. You may need to adjust the Pump to UV Chamber Adapter (Item # 22) so the screws align properly while the “O” ring for the Internal UV Housing and the “O” ring of the Pump to UV Chamber Adapter to make a proper seal (as shown in Fig – 9) (Item # 17). Fig. 9 Place the Biological Media Bag and follow Step – 1, Step – 2, and Step – 3 to install the layers and Fountain Assembly.
LIFEGARD UNO, DUO TRIO FILTER KIT INSTRUCTIONS – Includes Quiet One Pump R440021-UNO Filter Kit Up To 1000 Gallons R440022-DUO Filter Kit For Up To 1500 Gallons R440023-TRIO Filter Kit For Up To 2000 Gallons 24 UNO, DUO, TRIO Filter Kits Setup Positions for Single, Double or Triple Instructional Videos Available on our web site: www.lifegardaquatics.com Item Part No. Description Item Part No.
The UNO, DUO, TRIO FILTER SYSTEM is a compact filter for ponds and water gardens, easy to install and designed for easy maintenance. Besides offering 2 different fountain spray patterns, it performs three different filtering functions: 1. Multi Layer MECHANICAL Filtration to remove solids. 2. BIOLOGICAL Filtration to promote beneficial bacteria growth. 3.
Step – 2: Once all the parts are inspected for correct positioning make sure that the pump cable is running through the locks and is locked in place with the Rubber Cord Grommet (as seen in Fig. 2B). Step – 3: Correctly place the layer (Item # 1) back on the base by sliding the Locking notches in to the Notch Holders (see Fig – 3 and 3A). Similarly place the Housing Cover Top and Lock it in with the Locking Assembly (Fig – 3B and 3C).
Fig – 5A Fig – 5B Fig – 5C Pulling the pump Vertically will result in damaging the filter base and the pump. With the pump out now you can remove the grey volute by twisting it counter clockwise. This will expose the impeller and shaft of the pump. Inspect all parts for any debris. Use a brush to remove any debris. NOTE the position of the pump when it is locked onto the base. The pump is properly locked once it slides over the Locking Notch (as seen in Fig – 4C).
Step – 7: Adjust the UV Chamber housing and Align the holes for the locking screws. You may need to adjust the Pump to UV Chamber Adapter so the screws align properly (see Fig – 9C) while the “O” ring for the Internal UV Housing and the “O” ring of the Pump to UV Chamber Adapter make a proper seal (as shown in Fig – 9A). Once the pump and the UV Chamber Housing are aligned correctly the screw holes will fall in place (see Fig – 9B). Install the screws.
UV Installation: UV is an OPTIONAL add-on feature for UNO, DUO and TRIO Filter Kits. You can purchase it directly from the manufacturer (contact information listed below). Adding UV helps control Algae and Disease in your system. Fig – 10A shows the components of your UV Kit. Install the UV Bulb (Item # 13) into the Ballast Connecter Item # 14) (see Fig – 10B). Install the O-Ring (Item # 16) onto the Quartz Sleeve (Item # 15) as seen in Fig – 10C.
LIFEGARD UNO, DUO TRIO FILTER UNO, DUO, TRIO Filter Kits Setup Positions for Single, Double or Triple 24 R440011-UNO Filter For Up To 1000 Gallons R440012-DUO Filter For Up To 1500 Gallons R440013-TRIO Filter For Up To 2000 Gallons Instructional Videos Available on our web site: www.lifegardaquatics.com Item Part No. Description Item Part No.
Please Read Instructions before Installing The advanced features of this UNO, DUO, TRIO filter system allows efficient operation and if installed according to instructions, will keep the water in your pond or water garden crystal clear. The UNO, DUO, TRIO FILTER SYSTEM is a compact filter for ponds and water gardens, easy to install and designed for easy maintenance. Besides offering 2 different fountain spray patterns, it performs three different filtering functions: 1.
Fig – 3B Fig – 3 Pump Lock Notch Fig – 3A Pump Base Wall Fig – 3C Correct Installation – No Gap Fig – 3D Fig – 3E Step – 3 Removal of Optional UV Chamber Housing (Item # 11) and Pump Replacement Base (Item # 23). After removing the layers you will see the Biological Media Bag (Item # 10), UV Chamber Housing (Item # 11) and Pump Replacement Base (Item # 23). Take out the Biological Media Bag (Item # 10).
Step – 3: Correctly place the layer (Item # 1) back on the base by sliding the Locking notches into the Notch Holders see Fig – 5 and 5A. Similarly place the Housing Cover Top and make sure to align the notches for correct assembly as seen in Fig – 5B. Lock the Layer and Top Cover with the Locking Assembly (Item # 7,8 or 9) as seen in Fig – 5C. Now you are ready to put the 1" MPT x 90 Degree Elbow (Item #18) on the Locking Nut.
WARRANTY: Lifegard Aquatics warrants the original purchaser of the product against defective material and workmanship under normal use, for a period of 1 year from the date of purchase. Replacement liability in all events is limited to the replacing or repairing at Lifegard Aquatics sole discretion of any part or parts, which are defective in material or workmanship. Proof of purchase is required on all claims in the form of invoice copy, sales ticket, etc.