and push the pump into the grove until you hear a locking clock sound. Similarly push in the opposite direction to take the
pump out of the grove.
Vertical pull may result in damaging the base or the pump. With the pump out remove the grey pump volute by twisting it
counter clockwise. This will expose the impeller and shaft of the pump. Inspect all parts for any debris. Use a brush to
remove any debris.
Recommendation: It is recommended to use Lifegard Silicon Lubricant (Item # R172036) on all rubber O-rings and the
impeller and shaft of the pump. After servicing the pump replace the pump back onto the base by following Step – 4 in
reverse. Make sure to slide the pump back onto the base until it is locked and you hear a locking click. If the pump is not
all the way locked the UV chamber will not fit properly. Reinstall the Pump to UV Chamber Adapter (as shown in Fig – 6).
Step – 5: Run the pump cord along the cord holders on the base and reinstall the Rubber Cord Grommet (as shown in Fig
– 7) (Item # 20)
Step – 6: Start to reinstall the UV Housing Chamber (Item # 11) by first installing the open end of the Housing that goes
over the “O” ring for the Internal UV Housing (Item # 17). Slide it gently and press the end that connects to the pump by
sliding it onto the “O” ring of the Pump to UV Chamber Adapter (as shown in Fig – 8) (Item # 22).