TDS

TECHNICAL DATA SHEET
PHYSICAL PROPERTIES (FLOATING MULTILAYER MODULAR FLOORING) 6.0MM GAUGE / 12MIL WEAR LAYER
Collection
Plank - Wide
Size 7.5"x48" (190mm x 1219mm)
Overall Gauge 6.0mm (0.276”)
Wear Layer 12mil (0.30mm)
Top Layer 1.0mm (0.079”) LVT
Core 4.0mm (0.157”) Rigid Core
Core Density 1.5 grams / cm³
Pad 1.0mm (0.039”) HDPE
Use Light Commercial & Residential
Profile Uniclic Angle / Angle
Finish Enhanced Hard Mineral Urethane
Embossing(s) Natural Timber
Pieces/Carton 7 pieces
Coverage/Carton 18 Sq.Ft. (1.67 Sq.M.)
Limited Warranty
Limited Light Commercial
10 Years
Limited Residential -
Lifetime
STANDARDS SAFETY & PERFORMANCE
Standard Description Requirements Results
ASTM F970 Static Load No Requirements if Wear Layer < 20mil Passes Requirements
ASTM F970 Static Load Limit Test to Limit (±0.005”) 600 psi
ASTM F2199 Dimensional Stability ≤0.25% / lineal ft. Passes Requirements
ISO 24336 Swelling ≤1.5% after 24-hour immersion Passes Requirements
ISO 4918 Castor Wheel Test 25,000 cycles Passes Requirements
ASTM F925 Chemical Resistance No more than “Slight Change” Passes Requirements
ASTM F1514 Resistance to Heat Average ΔΕ < 8.0 Passes Requirements
ASTM F1515 Resistance to Light Average ΔΕ < 8.0 Passes Requirements
ASTM E648 Critical Radiant Flux (Radiant Panel) Class I: ≥ 0.45 W/cm
2
Passes Requirements
1
16 CFR 1500.44 Flammability ≤ 0.1 in/sec Passes Requirements
2
ASTM D2047 Coefficient of Friction (Slip Resistance) Not Applicable (No Official Requirements) ≥0.6 (Dry)
ASTM F963 Heavy Metals Refer to Standard Passes Requirements
ASTM D7823 Phthalates Refer to CPSIA
3
Passes Requirements
STANDARDS SOUND
Assembly
ASTM E90
ASTM E492
Results (Remarks)
6” Concrete Slab STC 51 IIC 53
All tested assemblies pass IBC
4
requirements of
STC ≥ 50 and IIC ≥ 50 for multi-story dwellings
8” Concrete Slab STC 54 IIC 57
6” Concrete Slab with Drop-Ceiling STC 61 IIC 67
Notes
1) ASTM E648 - Critical Radiant Flux (Radiant Panel): Passes Requirements for Class I per International Building Code (IBC) 2018 & NFPA 101 Life Safety Code
2) 16 CFR 1500.44 The burning rate shall not exceed 0.1 inch per second along the longest dimension of the product.
3) CPSIA = Consumer Product Safety Improvement Act
4) IBC = International Building Code
Effective: April 6, 2020 Page 1 of 1 (866) 843-8453 | homedepot.com