TDS

TECHNICAL DATA SHEET
Effective: October 10, 2022 Page 1 of 1 (866) 843-8453 | homedepot.com
PHYSICAL PROPERTIES (FLOATING MULTILAYER MODULAR FLOORING) – 7.0 MM GAUGE / 22 MIL WEAR LAYER
Product LifeProof™ Wide Pro
Size 8.66 in x 47.64 in (220 mm x 1210 mm)
Overall Gauge 7.0 mm (0.276 in)
Wear Layer 22 mil (0.55 mm)
Pad 1.0 mm (0.039 in) HDPE
Use Commercial & Residential
Profile Square Edge
Finish ScratchProtect™
Embossing(s) Handscraped, Natural Timber, In-Register
Coverage/Piece 2.87 sq.ft (0.266 sq.m)
Coverage/Carton 7 pieces – 20.06 sq.ft (1.86 sq.m)
Limited Warranty 20-Year Commercial & Lifetime Residential
STANDARDS – MANUFACTURING & USAGE (ASTM F3261)
STANDARD DESCRIPTION REQUIREMENTS RESULTS
ASTM F3261 Physical Characteristics / Tolerances Refer to standard Passes Requirements
1
ASTM F1914 Residual Indentation Average: ≤ 0.007 in (0.18 mm) Passes Requirements
ASTM F1914 Surface Integrity No Puncture Through Wear Layer / Décor Layer Passes Requirements
ISO 23999 Dimensional Stability Average ≤ 0.2% / lineal ft. (305 mm) Passes Requirements
ISO 23999 Curling ≤ 0.080 in. (2.0 mm) Passes Requirements
ASTM F925 Chemical Resistance No more than “Slight Change Passes Requirements
ASTM F1514 Resistance to Heat Average ΔΕ < 8.0 Passes Requirements
ASTM F1515 Resistance to Light Average ΔΕ < 8.0 Passes Requirements
ASTM F970 Static Load 0.005 in, 250 psi 0.005 in, ≥ 500 psi
STANDARDS – SAFETY & PERFORMANCE
STANDARD DESCRIPTION REQUIREMENTS RESULTS
ASTM E648 Critical Radiant Flux (Radiant Panel) Class I: ≥ 0.45 W/sq.cm Passes Requirements
2
ASTM E662 Smoke Density Flaming & Non-Flaming ≤ 450 Passes Requirements
3
ASTM D2047 Coefficient of Friction (Slip Resistance) N/A (No Official Requirements) ≥ 0.6 (Dry)
ASTM F963 Heavy Metals Refer to Standard (Table 1) Passes Requirements
CPSC-CH-C1001-09.3 Phthalates Per CPSIA
4
< 0.1% per Substance Passes Requirements
ASTM G21 Antifungal Activity N/A (No Official Requirements) Top: 0; Bottom: 0
5
STANDARDS – SOUND
ASSEMBLY ASTM E90 ASTM E492 ASTM E2179 RESULTS (REMARKS)
6-in Concrete Slab STC 50 IIC 52 ΔIIC 23
All tested assemblies pass IBC
6
requirements of
STC ≥ 50 and IIC ≥ 50 for multi-story dwellings
6-in Concrete Slab with Drop-Ceiling STC 60 IIC 66 Not Applicable
Notes
1) ASTM F3261 - Physical Characteristics / Tolerances: includes Size, Squareness, Thickness, Thickness Swell, Wear Layer Thickness (Commercial Class), Flatness, Openings,
and Ledging.
2) ASTM E648 - Critical Radiant Flux (Radiant Panel): Passes Requirements for Class I per International Building Code (IBC) 2018 & NFPA 101 Life Safety Code.
3) ASTM E662 - Smoke Density: 450 is the limit established by many state, county, and/or local building and/or fire codes, but is not set as a limit for (resilient) flooring products
nationwide. Thus, Smoke Density requirements for flooring products may vary from jurisdiction to jurisdiction.
4) CPSIA = Consumer Product Safety Improvement Act.
5) ASTM G21 (Antifungal Activity): Top Surface (Finish Coating Layer) scored 0 (No Growth); Bottom Surface (Pad) scored 0 (No Growth).
6) IBC = International Building Code

Summary of content (1 pages)