TDS

TECHNICAL DATA SHEET
Effective: July 11, 2017 Page 1 of 2 (866) 843-8453 | homedepot.com
PHYSICAL PROPERTIES & PACKAGING (FLOATING MULTILAYER MODULAR FLOORING)
Construction
Extruded Vinyl Core
Top Layer
Pre-Attached Underlayment
6.5mm Gauge / 6mil Wear Layer – Multi-Width Plank
4.0mm (0.157") Rigid Core
1.5mm (0.059") Luxury Vinyl Tile (LVT)
1.0mm (0.039") HDPE with Ultra-Fresh
Use
Light Commercial & Residential
Size
3 Sizes/Widths:
4.25" x 47.64" (108mm x 1210mm)
5.59" x 47.64" (142mm x 1210mm)
9.84" x 47.64" (250mm x 1210mm)
Wear Layer 6mil (0.15mm)
Edge Detail Square Edge
Finish
Urethane with Enhanced
Ceramic Bead (ECB) & Ultra-Fresh
Embossing(s) Natural Timber, Sawcut
Gauge 6.5mm (0.256”)
Pieces/Carton 9 (3 Pieces per Size * 3 Sizes)
Coverage/Piece
Varies with Size:
4.25" x 47.64" (108mm x 1210mm) = 1.406 Sq.Ft. (0.131 Sq.M.)
5.59" x 47.64" (142mm x 1210mm) = 1.849 Sq.Ft. (0.172 Sq.M.)
9.84" x 47.64" (250mm x 1210mm) = 3.255 Sq.Ft. (0.302 Sq.M.)
Coverage/Carton 19.53 Sq.Ft. (1.815 Sq.M.)
Limited Warranty 5-Year Light Commercial / Lifetime Residential
NORTH AMERICAN STANDARDS – SAFETY & PERFORMANCE
Standard Description Requirements Results
ASTM E648
Radiant Panel (Critical Radiant Flux) Class I: ≥ 0.45 W/cm
2
Passes Requirements
ASTM E662 Smoke Density Flaming & Non-Flaming ≤ 450 Passes Requirements
ASTM D2047 Coefficient of Friction (Slip Resistance) N/A ≥0.6 (Dry)
ASTM F970 Static Load ±0.005”, 250-Lbs. Load Passes Requirements
SIM Test Static Load Limit Test to Limit ≥500 lbs.
ASTM F2199 Dimensional Stability ≤0.020"/Linear Foot Surpasses Requirements
ASTM F925 Chemical Resistance No more than “Slight Change” Surpasses Requirements
ASTM F1514 Resistance to Heat Average & Max ΔΕ < 8.0 Surpasses Requirements
ASTM F1515 Resistance to Light Average & Max ΔΕ < 8.0 Surpasses Requirements
ASTM G21
1
Antifungal Activity N/A Top: 0-1; Bottom: 0-1
ASTM F963 Heavy Metals Refer to Standard Passes Requirements
ASTM D7823 Phthalates Refer to Standard Meets CPSIA Guideliines
NALFA/ANSI STANDARDS (LF-01-2011) – PERFORMANCE
Standard
Description
Class 1
(Residential)
Class 2
(Light Commercial)
Class 3
(Commercial)
Class 4
(Heavy Commercial)
Meets
Requirements
Section 3.2 Thickness Swell ≤18% ≤16% ≤16% ≤12% Classes 1-4
Section 3.5
2
Large Ball IR >800mm/31.5” >1,000mm/39.4” >1,200mm/47.3” >1,400mm/55.1” Classes 1-4
Section 3.6
2
Small Ball IR >200mm/7.9” >200mm/7.9” >350mm/13.8” >500mm/19.7” Classes 1-4
Section 3.10 Surface Bonding 1 N/mm
2
1.25 N/mm
2
1.25 N/mm
2
1.5 N/mm
2
Classes 1-4

Summary of content (2 pages)