Instructions / Assembly

3
Residential Installation Guide –
Sheet Vinyl Flooring
This document is reviewed on an ongoing basis.
06/01/18
Acceptable Underlayments:
• Wood Underlayment
Wood underlayment panels require a double layer construction and must be underlayment grade as specied
and warranted by the manufacturer. Always fasten underlayment panels in accordance with the manufacturers
recommendations. Any failure of the underlayment or Mohawk ooring as a result of the underlayment is NOT
the responsibility of Mohawk. Any porous wood underlayment must be primed.
• Concrete
• VCT (well bonded, on and above grade)
• Ceramic (well bonded) with a skim coat
• Terrazzo (well bonded)
• Self-leveling and patching compounds (latex fortied Portland cement based only)
• Resilient oor (no more than 2 layers, well bonded, non-cushioned – residential applications only)
• Radiant heat oors (not exceeding 85°F (29°C) and approved by the manufacturer for the use of their product
with resilient vinyl ooring applications)
• Gypcrete can be utilized when necessary due to radiant heat and in high rise buildings. Gypcrete must be sealed
using IVC FLEX-PRIM Acrylic Latex Primer to stabilize the surface for adhesive bond. All issues with gypcrete
cracking, crumbling, powdering and resulting in the release of adhesive bond are NOT warranted by Mohawk.
• OSB (underlayment grade)
OSB underlayment panels must be underlayment grade as specied and warranted by the manufacturer.
Underlayment panels and joints must be fastened and reinforced according to manufacturer’s instructions.
Completely sand the oor with a oor sander, so that the oor is smooth and at. Note: The chips in OSB
overlap. Without sanding properly, OSB has high and low spots throughout the oor that could telegraph
through the vinyl.
- Surface must be primed using IVC FLEX-PRIM Acrylic Latex Primer.
• Particle board (underlayment grade)
Particle board underlayment panels must be underlayment grade as specied and warranted by the
manufacturer.
- Surface must be primed using IVC FLEX-PRIM Acrylic Latex Primer.
Floor Preparation:
Floor must be clean, smooth, at and dry. Remove all foreign substances such as wax, grease, dirt, construction
markings and contaminants, and any substance or chemical that would interfere with a good bond. Fill all holes and
cracks with a latex fortied Portland cement based patching compound. Sand high spots to eliminate the possibility
of telegraphing. Prime oor if needed with IVC FLEX -PRIM Acrylic Latex Primer to prevent over absorption of
adhesives, dust containment, and to ensure a better bond of the adhesive to the suboor.