TM Congratulations. You have purchased a LifeSource state-of-the-art blood pressure monitor, one of the most technologically advanced yet easy to use products available in the marketplace today. This LifeSource monitor is designed to make your daily regimen useful, and convenient.
TABLE OF CONTENTS ? WHAT DISPLAY SYMBOLS MEAN MONITOR COMPONENTS ....................3 .........................4 HOW 702 WORKS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 BEFORE YOU START . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 SELECTING THE CORRECT CUFF . . . . . . . . . . . . . . . . . . . . . . 6 TAKING YOUR BLOOD PRESSURE . . . . . . . . . . . . . . . . 7 — 10 CHECK/ADJUST EXHAUST VELOCITY . . . . . . . . . . . . . 11 — 12 ❤ ABOUT BLOOD PRESSURE . . . .
? WHAT DISPLAY SYMBOLS MEAN Display Symbol Condition/ Cause Recommended Action Appears during measurement; blinks and beeps when pulse is detected. Remain still and refrain from talking; measurement in progress. Appears on display prior to and during measurement. Blinks if there is air in cuff at power up. Press exhaust button to release air. RE-MEASURE Measurement begun, but pressure is not sufficient for reading. Increase pressurization by 30 mmHg to 40 mmHg and repeat measurement.
MONITOR COMPONENTS ? AIR SOCKET PRESSURE AND PULSE DISPLAY SYSTOLIC DIASTOLIC (PULSE) UA-702 DIGITAL BLOOD PRESSURE MONITOR MEASURING PRESS EXHAUST RE-MEASURE BATTERY LOW RE-MEASURE POWER CUFF POWER BUTTON AIR CONNECTOR CUFF INFLATOR BULB EXHAUST VALVE AND ADJUSTMENT SCREW BATTERY COMPARTMENT LifeSource Health Line (Toll-Free): 1-888-726-9966 ? 4
? HOW 702 WORKS LifeSource Blood Pressure Monitors are easy to use, accurate and digitally display full measurement readouts. Our technology is based on the “oscillometric method” — a noninvasive blood pressure determination. The term “oscillation” refers to any measure of vibrations caused by the arterial pulse. The cuff is first inflated until the artery is fully occluded. Then, the monitor takes measurements while the cuff deflates.
SELECTING THE CORRECT CUFF Using the correct cuff size is important for an accurate reading. A cuff that is too large will produce a reading that is lower than the correct blood pressure; a cuff that is too small yields a measurement that is higher. With your arm hanging at the side of your body, measure the circumference of your upper arm at the midpoint between shoulder and elbow. RECOMMENDED CUFF SIZE REPLACEMENT CUFF MODEL# 5.1” - 7.9” (13-20cm) Small UA-279 7.5” - 12.
TAKING YOUR BLOOD PRESSURE Tips Tips for for Blood BloodPressure PressureMonitoring: Monitoring: ☞ Relax for about 5 to 10 minutes before measurement. ☞ Relax for about 5 to 10 minutes before measurement. ☞ Remove constricting clothing and place cuff on bare arm. ☞ Remove constricting clothing and place cuff on bare arm. ☞ Unless your physician recommends otherwise, use left arm ☞ Unless your physician recommends otherwise, use left arm to measure pressure. to measure pressure.
TAKING YOUR BLOOD PRESSURE ☞ IMPORTANT: Measure pressure at the same time each day. 4. Press the POWER button. 5. Watch for all display symbols to appear briefly, followed by a zero, indicating that monitor is ready for measurement. 6. Watch the display and squeeze the bulb quickly until cuff pressure reaches about 30 mmHg to 40 mmHg above expected systolic pressure.
TAKING YOUR BLOOD PRESSURE 7. Sit quietly during measurement. Pressure values are displayed at left, then right, along with ❤ symbol blinks and beeps with pulse beat. NOTE: If you wish to stop inflation at any time, press the exhaust valve to release air. 8. Wait for the long beep, indicating that the measurement is complete. Your systolic pressure will appear on the left and your diastolic pressure on the right of the display screen, alternating with pulse reading. 9.
TAKING YOUR BLOOD PRESSURE 10.Remove cuff and make a note of your blood pressure and pulse rate on the chart (see page 16), indicating date and time of measurement. We advise that you record the date and time after each measurement because an accurate blood pressure history relies not on single or sporadic readings but on a pattern over time. NOTE: If you wish to take your blood pressure again, relax and wait 5–10 minutes to enable the flow of blood in the arm to return to normal.
CHECK/ADJUST EXHAUST VELOCITY Exhaust velocity is the rate at which the air pressure in the cuff deflates during the course of measurement. It is preset at the factory and generally does not need any further adjustment. NOTE: The exhaust rate of your monitor was preset and tested at the factory to ensure proper measurement. The rate set is dependent on cuff size, not arm size. If using a cuff other than the one shipped with the unit, you may need to adjust the exhaust velocity rate.
CHECK/ADJUST EXHAUST VELOCITY 4. Watch the display screen. As pressure automatically decreases, diastolic numbers should decline in increments of 2 to 5 mmHg. If the exhaust velocity range is not within 2 to 5 mmHg, make the following adjustment with the unit turned off: 1. The adjustment screw is located on the exhaust valve attached to the inflator bulb. It is covered by a thin grey protection cap with a hole in the center.
ABOUT BLOOD PRESSURE ❤ What What Is Is Blood BloodPressure? Pressure? Blood pressure pressureisisthe theforce forceexerted exertedbyby blood against Blood blood against thethe walls of walls of the Systolic arteries.pressure Systolicoccurs pressure occurs whencontracts; the heart the arteries. when the heart contracts;pressure diastolic pressure when the heart expands. diastolic occurs whenoccurs the heart expands.
ABOUT BLOOD PRESSURE ❤ Assessing AssessingHigh HighBlood BloodPressure Pressure The following followingstandards standardsfor forassessing assessing high blood pressure The high blood pressure (without regard regardtotoage) age)have havebeen beenestablished established guideline. (without by as thea National Institutes of Health JNCVI.
❤ ABOUT BLOOD PRESSURE Why Measure MeasureBlood BloodPressure Pressure Home? Why atat Home? It is now now well wellknown knownthat, that,for formany manyindividuals, individuals, blood presblood sure readings taken in aindoctor’ s office ororhospital pressure readings taken a doctor’ s office hospitalsetting setting might be elevated as a result of apprehension and anxiety. might be elevated as a result of apprehension and anxiety.
TM B L O O D P R E S S U R E Name: DATE Age: AM SYS/DIA PULSE R E C O R D Weight: PM SYS/DIA PULSE 1/14 9:30 132/98 P 69 6:30 128/87 P 63 E X A M P L E LifeSource Health Line (Toll-Free): 1-888-726-9966 ❤ 16
✓ IMPORTANT INFORMATION Please read this important information before using your monitor. ☞ ☞ ☞ ☞ ☞ ☞ ☞ Please remember that only a medical practitioner is qualified to interpret your blood pressure measurements. Use of this device should not replace regular medical examinations. Have your physician review your procedure for using this device. He or she will want to verify blood pressure measurements before prescribing or adjusting medications.
SPECIFICATIONS SPECIFICATIONS ✓ Model . . . . . . . . . . . . . . . . . . .UA-702 Type . . . . . . . . . . . . . . . . . . . . .Oscillometric Display . . . . . . . . . . . . . . . . . .Digital, 10-mm character height Pressure/pulse displayed alternately Measurement range . . . . . . . . .Pressure: 20 mmHg to 280 mmHg Pulse: 40 pulses to 200 pulses/minute Accuracy . . . . . . . . . . . . . . . . .Pressure: +3 mmHg or 2%, whichever is greater Pulse: +5% Pressurization . . . . . . . . . . . .
CONTACT INFORMATION Our products products are are designed designedand andmanufactured manufacturedusing usingthe thelatest latest scientific and and technological technologicalmethods, methods,and andoffer offeraccurate, accurate,easy easyto use, home monitoring andand treatment options. The Our product to use, home monitoring treatment options.
CONTACT INFORMATION IMPORTANT! If You Need Assistance with the Set-Up or Operation We Can Help! Please call us FIRST before contacting your retailer at LifeSource Health Line 1-888-726-9966 - Toll Free 1-800-463-5414 - In Canada A specially trained representative will assist you A division of A&D Engineering, Inc. 1555 McCandless Drive Milpitas, CA 95035 www.LifeSourceOnline.com LifeSource is a trademark of A&D Medical. ©2003 A&D Medical. All rights reserved.