Product Features: • 3 Input Ports • Unique Design • Comfort and Stylishness Models: • LA-Round • LA-Elongated • LA-European Design Installation Manual
Please read all of the following instructions before beginning installation. 1. Check to make sure the toilet functions properly before making any construction changes to the property. 2. Important: Do not flush anything other than organic human waste and toilet tissue. 3. Do not allow the unit to freeze. 4. Make sure any pipes exposed to freezing temperatures are insulated. 5. Check plumbing fixtures attached to the pump for leaks. 6.
2 Parts Included 1 1. Water Tank 2. Rear Discharge Toilet and Lid Dual Button 2 Lever Macerator Parts: 1. Attachment Fitting 2. Hose Clamps 3. Cover Plate 4. Screw Clamps 1 5. Discharge Pipe 6 6.
3 Technical Specifications Macerator Specifications Power Supply/Frequency Input Ports Current/Wattage Circuit Requirement Duty Cycle 120V/60Hz 3 800W Dedicated 15 AMP 38GPM, 22 ft., 295 ft., H Run 1 Plus HP Pump Toilet Models Specifications LA-European Model Specifications LA-Round Model Specifications LA-Elongated Model Specifications Toilet Material Ceramic Ceramic Ceramic Flush Type Dual Button Lever Lever Color White White White Toilet Depth 27 in. 24 in. 27 in.
Plumbing Layout For Your Consideration Fig.1: Pumping Head 1) Outlet check valve is necessary 2) Install an extra manual check valve for repair (Suggestion) 3) Lift the shower 6 ½ inches high, when you connect the side inlet 4) Using filter in shower & lavatory to reduce hair come into machine Fig.
5 Installation Options 3” Rigid Pipe. Must not exceed 36” Option #1 Pump and Plumbing Behind Wall For this method, you will need a 3” rigid pipe and a 3” pipe coupler (not included) to achieve proper drainage slope. Distance between toilet outlet and pump inlet cannot not exceed 36”. Allow additional space for maintenance purposes. Option #2 Exposed Pump with Plumbing In Wall The pump is placed in front of the wall with the plumbing within the wall. Allow additional space for maintenance access purposes.
Toilet and Pump Installation 6 Check the following before starting installation: Floor site should be finished and level. Check for clearance of doors and cabinets as well as any shower enclosure. Ensure that all plumbing and electrical fixtures do not interfere with placement of bathroom fixtures. Rough plumbing and electrical are completed to code. Placement of the electrical outlet must also meet local code. It is recommended to leave a 40” distance from bathtub/shower and within 6’ of the pump.
7 Toilet and Pump Installation Part 1: Attaching Connections Discharge Vent Cutting/Grinding Blade Shower/Tub Connection Vent Line Sink Connection Shower/Tub/Sink Discharge The macerating unit must be vented. It has 2 inlets on the top of the cover: a 1 ½” cap and a hole of smaller diameter. To connect to the side entries of the case, use the side connector. These macerating units have an elbow and a bushing.
Toilet and Pump Installation Part 2: Connection to Bath/Shower/Sink Before making any connections, make sure there is proper slope of all horizontal runs. Bath and Shower Attachment: 1. For proper draining it is essential to elevate the shower/tub drain to a minimum of 9” above the finished floor of the installed pump. If applicable, adjust the height of the shower/tub drain upwards to allow proper grade for the plumbing connection to the pump. 2.
Toilet and Pump Installation Part 3: Connecting Toilet and Pump The following instructions apply for Option 1 seen on page 5. NOTE: Make sure the floor holes are drilled before you begin the following steps. 1. Drill a hole in the wall sized to accommodate pipe slope. 2. Position clamp onto the toilet outlet. Hint: Apply soapy water to lubricate for easier clamp application; make sure you use non-petroleum-based products only! 3.
Toilet and Pump Installation Part 4: Toilet Assembly NOTE: Assemble water tank as explained in the supplied instruction sheet, before proceeding with the following steps. 1. Check to make sure toilet is leveled before securing the toilet to the floor. 2. Install water tank in place. It is recommended to apply caulk around the base of the opening. 3. Secure the water tank with the provided nuts and bolts. 4. Verify that proper placement of the hose is established. 5.
Fig.3: Pumping Head Fig.4: Distance Min.
Fig.5: Angle We suggest to using 2pcs 45° elbow instead of 1pc 90° elbow Fig.
Warning 13 The use of this product requires experience with, and knowledge of the product. Persons with reduced physical, sensory, or mental capabilities must not use this product unless they are under supervision or have been instructed in the use of the product by a person responsible for their safety. Children must not use or play with this product. 1.
4. Installation 14 Caution • Do not pull or lift the product by the supply cable. • The product must be accessible for maintenance and repair. • The product must be placed in a frost- free room to prevent the pumped liquid from freezing. Make sure that all external pipework is adequately insulated. Note • The discharge pipe must be made of rigid material, such as copper, or of rigid PVC with solvent-welded joints.
6.2 Service Instructions Thanks to the product design, service is easy in case of malfunction or blocked pump. Digits in the following sections refer to the pictures in the appendix at the end of this booklet. Warning Before carrying out any service work, remove the fuse, pull out the plug, or switch off the power supply. Make sure that the power supply cannot be accidentally switched on. All rotating parts must have stopped moving. The product must only be serviced by a trained service personnel.
7. Fault Finding 16 Warning Remove the fuse, pull out the plug, or switch off the power supply. Make sure that the power supply cannot be accidentally switched on. All rotating parts must have stopped moving. The product must only be serviced by trained service personnel. Fault 1. Motor does not start when the level in the tank reaches the start level. 2. Motor hums but does not operate. 3. Motor runs continuously or at irregular intervals. Cause Reestablish the power supply. Replace the fuse.
17 8. Maintenance DISCONNECT THE ELECTRICAL POWER SUPPLY, BEFORE ATTEMPTING ANY WORK ON THE UNIT. No need of any particular maintenance. This unit is fitted with an active carbon filter, and requires no external venting. Correct disposal of this product This marking shown on the product or its literature, indicates that it should not be disposed with other household wastes at the end of its working life.
System Operation 18 What to Expect This toilet operates on a different principle than a typical siphon toilet, resulting in a different sound and flush action. When activated, the pump pulses a few times. Cleaning Use only non-abrasive, non-petroleum products to clean the pump. Prime the Pump If pump initially runs for more than 10 seconds, prime the pump as follows: a. Unplug cord from wall outlet. b. Wait 15 seconds. Plug cord back into wall outlet. c. Flush again.
ATTENTION: Do not return any merchandise to the vendor.
IMPORTANT When claiming a warranty repair, you will need the information you have written down below. Please ensure that you have all particulars when requesting work.