Installation Guide

6.2 Service Instructions
Thanks to the product design, service is easy in case of malfunction or blocked pump.
Digits in the following sections refer to the pictures in the appendix at the end of this booklet.
Warning
Before carrying out any service work, remove the fuse, pull out the plug, or switch off the power
supply. Make sure that the power supply cannot be accidentally switched on. All rotating parts
must have stopped moving. The product must only be serviced by a trained service personnel.
Note
Make sure that the little tube in the top of the pipe did not become blocked when you cleaned
the pipe!
Caution
Lubricate the sealing area of the pressure switch for easier fitting.
Foreign Body in Tank
If the water level in the tank is above the motor flange, drain the tank by means of the drain
hose (accessory).
Note
Lift the unit vertically before tilting it!
Warning
Beware of the sharp edges on the grinder. Wear protective gloves.
15