Installation Guide
System Operation
Cleaning
Use only non-abrasive, non-petroleum products to clean the pump.
What to Expect
This toilet operates on a different principle than a typical siphon toilet, resulting in a different sound
and flush action. When activated, the pump pulses a few times.
Prime the Pump
If pump initially runs for more than 10 seconds, prime the pump as follows:
a. Unplug cord from wall outlet.
b. Wait 15 seconds. Plug cord back into wall outlet.
c. Flush
again. If pump runs more than 10 seconds, repeats steps a-c
Winterization
If the Lift Assure system is exposed to freezing temperatures, please make sure that all fixtures,
inlets, and discharge lines are winterized using non-toxic propylene glycol (RV Marine AntiFreeze).
Use sufficient quantity of antifreeze to ensure all pipes are protected.
First, you must shut off the water supply. Flush toilet to empty the tank. Pour RV/Marine Anti
freeze
into toilet and all fixtures. Press manual switch to run antifreeze through system.
Clearing Debris from Pump
While the Lift Assure does not need any maintenance under normal conditions, it is okay to clean
out the macerating unit once a year. Do not use bleach. The macerating unit starts automatically
once the toilet is flushed or the other bathroom appliance discharge and ceases operation once the
contents have finished pumping.
18