User Guide

12 Safety Information
Doc 01-G0547
Rev D
Single Phase 3 Phase
WIRE
GAUGE
HP 115 VAC 230 VAC 230 VAC 460 VAC 575 VAC
6
1/3
1/2
3/4
1
1-1/2
2
684
473
324
237
158
--
3,077
2,051
1,231
947
648
437
4,737
2,842
2,030
1,421
947
711
14,211
14,211
7,105
5,684
4,060
2,842
35,527
17,764
11,842
8,882
5,921
4,441
8
1/3
1/2
3/4
1
1-1/2
2
432
299
204
149
100
--
1,942
1,295
777
597
409
299
2,990
1,794
1,281
897
589
448
8,969
8,969
4,484
3,587
2,562
1,794
22,422
11,211
7,474
5,605
3,737
2,803
10
1/3
1/2
3/4
1
1-1/2
2
271
187
128
94
62
--
1,218
812,
487,
375,
256
187
1,876
1,125
804
563
375
281
5,627
5,627
2,814
2,251
1,608
1,125
14,068
7,034
4,689
3,517
2,345
1,758
12
1/3
1/2
3/4
1
1-1/2
2
170
117
80
59
39
--
763
509
305
235
161
117
1,175
705
503
352
235
175
3,524
3,524
1,762
1,410
1,007
705
8,810
4,405
2,937
2,203
1,468
1,101
Table 5
NOTE: Calculated using NEC guidelines. Local codes and conditions must be reviewed for suitability
of wire installation. Master/Slave units must be installed on separate circuits.
Control Wiring
Volt Max. Dist. (Ft.) Wire Gage
24 1000 18
Table 6