Owners manual

39
ERROR CODES continued...
Some errors are saved in the error code history and some are not. If an error is not saved it will briefly appear on the error code display as it occurs,
then disappear.
TROUBLESHOOTING
Code Error Meaning Solution Saved
67 Wireless edge triggered more than 3 minutes Check wired input for wiring issue or obstruction. YES
68 Wireless edge loss of monitoring Check wireless edge inputs. YES
69
Wireless edge triggered IF an obstruction occurred, no action required. If an obstruction did
NOT occur, check inputs and wiring.
NO
70
CLOSE EYE/INTERRUPT triggered, causing
reversal, preventing close, or resetting TTC (main
board)
IF an obstruction occurred, no action required. If an obstruction did
NOT occur, check alignment, inputs, and wiring.
NO
71
CLOSE EDGE triggered, causing reversal,
preventing close, or cancelling TTC (main board)
IF an obstruction occurred, no action required. If an obstruction did
NOT occur, check alignment, inputs, and wiring.
NO
72
OPEN EYE/EDGE triggered, causing reversal or
preventing opening (main board)
IF an obstruction occurred, no action required. If an obstruction did
NOT occur, check alignment, inputs, and wiring.
NO
73
CLOSE EYE/INTERRUPT triggered, causing
reversal, preventing close, or resetting TTC
(expansion board)
IF an obstruction occurred, no action required. If an obstruction did
NOT occur, check alignment, inputs, and wiring.
NO
80
Close input (EYE/EDGE) communication fault
(secondary control box)
Check the connections between the main board and the secondary
operator.
YES
81
Open input (EYE/EDGE) communication fault
(secondary control box)
Check the connections between the main board and the secondary
operator.
YES
91
Force reversal (Arm 1) Check for obstruction. If no obstruction, check that the operator arm is
engaged and free to move. Refer to Limit and Force Adjustment
section, and Obstruction Test.
YES
92
Force reversal (Arm 2) Check for obstruction. If no obstruction, check that the operator arm is
engaged and free to move. Refer to Limit and Force Adjustment
section, and Obstruction Test.
YES
93
RPM / STALL Reversal (Arm 1) Check for obstruction. If no obstruction, check the operator cable
wiring and that the operator arm is engaged and free to move. Replace
the operator arm if necessary.
YES
94
RPM / STALL Reversal (Arm 2) Check for obstruction. If no obstruction, check the operator cable
wiring and that the operator arm is engaged and free to move. Replace
the operator arm if necessary.
YES
99 Normal Operation No action required YES