Installation Instructions
4
www.lightengineering.net
2 - PREPARATION
2.1 CUTTING
Diameter: 38mm
Diameter: 34,5mm
Min. 12,5mm
Diameter: 35mm
3 - USE OF THE SENSOR
There is two selectionable functioning mode:
AUTOMATIC: when the sensor is turn on, the light turn on automatically while it detects a movement and turn the light off
after a pre-set time.
It’s possible to set a brightness threshold to avoid the turn on of the light if the environmental light is enought. The de-
tection area, the timed on and the ebrightness threshold can be set with the procedure explained in paragraph 5.
MANUAL:
if the sensor is off, the central button can be used to send a command:
SHORT PRESS= On/Off
LONG PRESS= Dimmer Down and Dimmer Up
SHORT PRESS=
On/Off
LONG PRESS=
Dimmer down (red led)
and Dimmer Up (green led)
ON SENSORE
(led turns on for 2 sec.)
OFF SENSORE
(led make some flashes)