- Varec Radar Tank Gauge Model 7532 RTG Installation & Operations Manual

65
7532 Commissioning
6.5.2 Envelope curve with VU 331
After the basic setup, an evaluation of the measurement with the aid of the envelope
curve ("display" (09) function group) is recommended.
Function "plot settings" (09A)
Here you can select which information is shown on the display:
envelope curve
env. curve+FAC (for FAC see
7500 RTG "Service manual and description of
instrument functions
")
env. curve+suppress. (i.e. the tank map is also displayed)
Function "recording curve" (09B)
This function determines whether the envelope curve is read as:
single curve
or
cyclic
Note!
If the envelope curve mode is active on the display, the measured values are updated in
a slower cycle time. Thus, it is advisable to leave the envelope curve mode after the
measuring point has been optimized.
E
+
L00-FMRxxxxx-07-00-00-en-004
E
+