Job Information Type:
Lytecaster
®
Performance Recessed CFL Downlighting 2001
Page 2 of 2 3 ¾" Aperture Vertical Open, Compact Fluorescent, Performance Series, Reflector Trim
18W TRIPLE TUBE LAMP, LUMEN RATING = 1200 LMS, ELECTRONIC BALLAST, CL FINISH TRIM
13W TRIPLE TUBE LAMP, LUMEN RATING = 900 LMS, ELECTRONIC BALLAST, CL FINISH TRIM
1
56
113
169
225
60˚
30˚
13W QUAD TUBE LAMP, LUMEN RATING = 900 LMS, ELECTRONIC BALLAST, CL FINISH TRIM
1
50
100
150
200
60˚
30˚
COEFFICIENTS OF UTILIZATION
Ceiling 80% 70% 50% 30%
Wall 70 50 30 10 50 10 50 10 50 10 0
RCR Zonal Cavity Method - Effective Floor Reflectance = 20%
Room Cavity Ratio
0
61 61 61 61 60 60 57 57 55 55 52
1
58 56 54 53 55 52 53 50 51 49 47
2
54 51 48 46 50 45 48 44 46 43 41
3
50 46 42 40 45 39 44 39 42 38 37
4
46 41 38 35 41 35 40 34 38 34 32
5
43 38 34 31 37 31 36 30 35 30 29
6
40 34 30 27 34 27 33 27 32 27 26
7
37 31 27 24 31 24 30 24 29 24 23
8
35 29 25 22 28 22 28 22 27 22 21
9
33 26 22 20 26 20 25 20 25 20 19
10
31 24 21 18 24 18 24 18 23 18 17
Determined In Accordance With Current IES Published Procedures
Luminaire Input Watts = 17.0
ZONAL LUMENS AND PERCENTAGES
Zone Lumens %Lamp %Fixt
0-30 175.46 19.5 37.8
0-40 294.57 32.7 63.5
0-60 458.58 51 98.8
0-90 464.18 51.6 100
90-120 0 0 0
90-130 0 0 0
90-150 0 0 0
90-180 0 0 0
0-180 464.18 51.6 100
**
Efficiency = 51.6%
**
ZONAL LUMEN SUMMARY
Zone Lumens
0-10 19.02
10-20 60.03
20-30 96.41
30-40 119.11
40-50 113.45
50-60 50.56
60-70 5.48
70-80 .13
80-90 0
90-100 0
100-110 0
110-120 0
120-130 0
130-140 0
140-150 0
150-160 0
160-170 0
170-180 0
CANDLEPOWER SUMMARY
Angle 0˚ CP
0
190
5
195
10
207
15
212
20
213
25
209
30
202
35
191
40
175
45
151
50
108
55
53
60
18
65
3
70
1
75
0
80
0
85
0
90
0
SC = 1.5
CERTIFIED TEST REPORT NO. 3040FR
COMPUTED BY LSI PROGRAM
**TEST-LITE**
COEFFICIENTS OF UTILIZATION
Ceiling 80% 70% 50% 30%
Wall 70 50 30 10 50 10 50 10 50 10 0
RCR Zonal Cavity Method - Effective Floor Reflectance = 20%
Room Cavity Ratio
0 53 53 53 53 52 52 50 50 48 48 45
1 50 49 47 46 48 45 46 44 44 43 41
2 47 44 42 40 43 39 42 38 40 38 36
3 44 40 37 35 39 34 38 34 37 33 32
4 40 36 33 30 35 30 34 30 33 29 28
5 37 33 29 27 32 27 31 26 30 26 25
6 35 30 26 24 29 24 29 24 28 23 22
7 32 27 24 21 27 21 26 21 26 21 20
8 30 25 22 19 25 19 24 19 24 19 18
9 28 23 20 17 23 17 22 17 22 17 16
10 27 21 18 16 21 16 21 16 20 16 15
Determined In Accordance With Current IES Published Procedures
Luminaire Input Watts = 16.0
ZONAL LUMENS AND PERCENTAGES
Zone Lumens %Lamp %Fixt
0-30 55.05 17.2 38.4
0-40 257.28 28.6 63.7
0-60 399.05 44.3 98.8
0-90 403.78 44.9 100
90-120 0 0 0
90-130 0 0 0
90-150 0 0 0
90-180 0 0 0
0-180 403.78 44.9 100
**
Efficiency = 44.9%
**
CANDLEPOWER SUMMARY
Angle 0˚ CP
5
174
10
179
15
183
20
182
25
187
30
187
35
179
40
164
45
146
50
126
55
97
60
48
65
17
70
2
75
0
80
0
85
0
0
0
ZONAL LUMEN SUMMARY
Zone Lumens
0-10 17.21
10-20 52.09
20-30 85.75
30-40 102.22
40-50 95.83
50-60 45.94
60-70 4.74
70-80 0
80-90 0
90-100 0
100-110 0
110-120 0
120-130 0
130-140 0
140-150 0
150-160 0
160-170 0
170-180 0
SC = 1.4
CERTIFIED TEST REPORT NO. 3039FR
COMPUTED BY LSI PROGRAM
**TEST-LITE**
1
75
150
225
300
60˚
30˚
SC = 1.5
CERTIFIED TEST REPORT NO. 3038FR
COMPUTED BY LSI PROGRAM
**TEST-LITE**
COEFFICIENTS OF UTILIZATION
Ceiling 80% 70% 50% 30%
Wall 70 50 30 10 50 10 50 10 50 10 0
RCR Zonal Cavity Method - Effective Floor Reflectance = 20%
Room Cavity Ratio
0 56 56 56 56 55 55 53 53 50 50 47
1 53 52 50 49 50 48 49 47 47 45 43
2 50 47 44 42 46 42 44 41 43 40 38
3 46 42 39 37 42 37 40 36 39 35 34
4 43 38 35 32 38 32 37 32 36 31 30
5 40 35 31 29 34 28 33 28 32 28 27
6 37 32 28 25 31 25 30 25 30 25 24
7 35 29 25 23 29 23 28 23 27 22 21
8 32 27 23 21 26 21 26 20 25 20 19
9 30 24 21 19 24 19 24 18 23 18 18
10 28 23 19 17 22 17 22 17 22 17 16
Determined In Accordance With Current IES Published Procedures
Luminaire Input Watts = 22.0
ZONAL LUMENS AND PERCENTAGES
Zone Lumens %Lamp %Fixt
0-30 222.19 18.5 39
0-40 370.28 30.9 65.1
0-60 564.67 47.1 99.2
0-90 569.15 47.4 100
90-120 0 0 0
90-130 0 0 0
90-150 0 0 0
90-180 0 0 0
0-180 569.15 47.4 100
**
Efficiency = 47.4%
**
ZONAL LUMEN SUMMARY
Zone Lumens
0-10 23.94
10-20 75.59
20-30 122.65
30-40 148.09
40-50 136.28
50-60 58.12
60-70 4.48
70-80 .0
80-90 0
90-100 0
100-110 0
110-120 0
120-130 0
130-140 0
140-150 0
150-160 0
160-170 0
170-180 0
CANDLEPOWER SUMMARY
Angle 0˚ CP
0
239
5
246
10
260
15
266
20
271
25
267
30
255
35
238
40
215
45
180
50
130
55
59
60
19
65
1
70
0
75
0
80
0
85
0
90
0