Emergency Lighting Specification Sheet

631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2008 Philips Group • D0308
Job Information Type:
Job Name:
Cat. No.:
Lamp(s):
Notes:
C2 Series Emergency Lighting C2
Page 1 of 2 6 or 12 Volt 14 to 50 Watts Thermoplastic Housing
Lightolier is a Philips group brand
Features
1. Illumination: Allows up to four mounted lamp heads. The standard head
incorporates a high performance parabolic reflector with a wedge base
tungsten lamp. Allows maximum spacing between units along a path of
egress.
2. Housing: Constructed of 18 gauge steel with a white epoxy powder coat
finish. Designed for easy drop-in installation into suspended ceilings.
3. Electronics: 120/277 VAC dual voltage input with surge-protected, solid-
state circuitry. Charging system is complete with low voltage disconnect, AC
lockout, brownout protection, AC indicator lamp and test switch.
4. Battery: Maintenance free, sealed lead calcium battery has an estimated
service life of 5 years, and an operating temperature range of 65°F (19°C)
to 85°F (3C). Maintenance free, sealed nickel cadmium battery has an
estimated service life of 10 years, and an operating temperature range of
20°F (-C) to 95°F (35°C).
5. Input Power Requirements: 120 VAC - 0.18 amps, 20 watts;
277 VAC - 0.08 amps, 20 watts
Code Compliance
UL 924 listed.
Options
SD = Self-Diagnostics
SA = Self-Diagnostics with Alarm
T1 = 120 VAC Time Delay
T2 = 277 VAC Time Delay
V = Voltmeter
A = Ammeter
F1 = 120 VAC Fuse
F2 = 277 VAC Fuse
P1 = 120 VAC Power Switch
P2 = 277 VAC Power Switch
Multiple option configurations may void UL listing. Consult factory for specifics.
How to Specify:
SERIES DC VOLTAGE BATTERY # OF LAMP
HEADS HEADS
C2
C2 = Recessed
Emergency Lighting
Unit
6V Round Wedge Base
RT6 = 5.4W Tungsten
RT7 = 7.2W Tungsten
RT9 = 9W Tungsten
RH7 = 7W Halogen
RH10 = 10W Halogen
RH12 = 12W Halogen
12V Round Wedge Base
RT9 = 9W Tungsten
RT12 = 12.5W Tungsten
RT18 = 17.9W Tungsten
RH12 = 12W Halogen
4 = Four
3 = Three
2 = Two
1 = One
Blank = No Lamp Heads
1 = 6 volt
2 = 12 volt
6V, Lead Calcium
25L = 25W Unit
50L = 50W Unit
6V, Nickel Cadmium
14N = 14W Unit
25N = 25W Unit
12V, Lead Calcium
50L = 50W Unit
12V, Nickel Cadmium
25N = 25W Unit
50N = 50W Unit
12.0”
(30.5 cm)
17”
(43.2 cm)
5.8”
(14.7 cm)
24.0”
(61.0 cm)
Recessed depth is 4.3”
6.0”
(15.2 cm)
For additional lamp heads, see
RT66 Specification Sheet
The C2 Series provides low profile, recessed emergency lighting for commercial interiors. It is also available as a master unit for remote operation.