Job Information Type:
CEILING 80% 70% 50% 30%
WALL 70 50 30 10 50 10 50 10 50 10 0
RCR
0 1.11 1.11 1.11 1.11 1.08 1.08 1.03 1.03 .99 .99 .93
1 1.08 1.06 1.04 1.03 1.04 1.01 1.00 .98 .97 .95 .91
2 1.05 1.02 1.00 .98 1.00 .97 .97 .94 .95 .93 .89
3 1.02 .99 .96 .94 .97 .93 .96 .92 .93 .90 .88
4 1.00 .96 .93 .91 .95 .90 .93 .89 .92 .88 .86
5 .98 .93 .90 .88 .93 .88 .91 .87 .90 .86 .85
6 .96 .91 .88 .86 .91 .86 .90 .85 .88 .85 .83
7 .94 .89 .86 .84 .89 .83 .87 .83 .86 .83 .82
8 .92 .87 .84 .82 .86 .81 .86 .81 .85 .81 .80
9 .90 .85 .82 .80 .85 .80 .84 .80 .83 .79 .78
10 .88 .83 .80 .78 .83 .78 .82 .78 .82 .78 .77
LUMINAIRE INPUT WATTS = 44
ANGLE MEAN CP LUMENS
0 6714
5 6480 607
10 5770
15 3724 1045
20 1533
25 496 310
30 156
35 72 62
40 93
45 3 19
`50 0
55 0 0
60 0
65 0 0
70 0
75 0 0
80 0
85 0 0
90 0
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE
0-30 1962 89.22 96.05
0-40 2024 92.03 99.07
0-60 2043 92.89 100
0-90 2043 92.89 100
40-90 18 0.86 0.93
60-90 0 0 0
90-180 0 0 0
0-180 2043 92.89 100
39W PAR30L PHILIPS FL MH LAMP, LUMEN RATING = 2200 LMS, AROMAT 39W ELECTRONIC BALLAST, CL FINISH REFLECTOR
Coefficients of Utilization
** EFFICIENCY = 92.9% ** CERTIFIED TEST REPORT NO. 2462FR, DATE: FEB 19, 2004.
COMPUTED BY LSI PROGRAM **TEST-LITE**
SC = .5
CANDLEPOWER DISTRIBUTION
CEILING 80% 70% 50% 30%
WALL 70 50 30 10 50 10 50 10 50 10 0
RCR
0 1.10 1.10 1.10 1.10 1.08 1.08 1.03 1.03 .99 .99 .93
1 1.07 1.05 1.03 1.02 1.03 1.00 .99 .97 .96 .94 .90
2 1.04 1.01 .98 .96 .99 .95 .96 .93 .94 .91 .88
3 1.01 .97 .94 .92 .96 .91 .94 .90 .92 .89 .86
4 .98 .94 .91 .89 .93 .88 .91 .87 .90 .86 .84
5 .96 .91 .87 .85 .90 .85 .89 .84 .87 .83 .82
6 .94 .89 .85 .83 .88 .82 .87 .82 .86 .81 .80
7 .91 .86 .82 .80 .85 .79 .84 .79 .83 .79 .78
8 .89 .83 .80 .78 .82 .77 .82 .77 .81 .77 .76
9 .86 .81 .78 .75 .80 .75 .80 .75 .79 .74 .73
10 .84 .79 .75 .73 .78 .73 .78 .73 .77 .73 .72
LUMINAIRE INPUT WATTS = 78
ANGLE MEAN CP LUMENS
0 10853
5 10183 962
10 9105
15 7452 2043
20 4818
25 2188 1173
30 943
35 239 260
40 233
45 20 53
50 1
55 0 0
60 0
65 0 0
70 0
75 0 0
80 0
85 0 0
90 0
70W PAR30L PHILIPS FL MH LAMP, LUMEN RATING = 4850 LMS, AROMAT 70W ELECTRONIC BALLAST, CL FINISH REFLECTOR
Coefficients of Utilization
LUMINANCE SUMMARY CD. / SQ. M.
ANGLE MEAN CD/SQ M
45 1583
55 0
65 0
75 0
85 0
CANDLEPOWER DISTRIBUTION
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE
0-30 4178 86.15 93.03
0-40 4437 91.5 98.81
0-60 4491 92.6 100
0-90 4491 92.6 100
40-90 53 1.1 1.19
60-90 0 0 0
90-180 0 0 0
0-180 4491 92.6 100
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
1,125
3,250
4,875
6,500
30°
60°
2,500
5,000
7,500
10,000
30°
60°
** EFFICIENCY = 92.9% ** CERTIFIED TEST REPORT NO. 2463FR, DATE: FEB 19, 2004.
COMPUTED BY LSI PROGRAM **TEST-LITE**
SC = .6
LUMINANCE SUMMARY CD. / SQ. M.
ANGLE MEAN CD/SQ M
45 195
55 0
65 0
75 0
85 0