User Guide
Calculite
®
HID Downlight C9E28VW
Page 2 of 2 9" Aperture, ED28 (Enclosed) Metal Halide, Wide Beam
Lightolier a Genlyte Thomas Company www.lightolier.com
631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
© 2003 Genlyte Thomas Group LLC (Lightolier Division) • A0504 PJF6/2
Job Information Type:
CEILING 80% 70% 50% 30%
WALL 70 50 30 10 50 10 50 10 50 10 0
RCR
0 .65 .65 .65 .65 .64 .64 .61 .61 .58 .58 .55
1 .62 .61 .60 .58 .60 .57 .57 .56 .55 .54 .51
2 .59 .57 .55 .53 .56 .52 .54 .51 .53 .50 .48
3 .56 .53 .50 .48 .52 .48 .51 .47 .49 .46 .45
4 .54 .49 .46 .44 .49 .44 .48 .43 .47 .43 .42
5 .51 .46 .43 .40 .45 .40 .44 .40 .44 .39 .38
6 .48 .43 .40 .37 .42 .37 .42 .37 .41 .36 .35
7 .45 .40 .36 .34 .39 .34 .39 .34 .38 .33 .32
8 .42 .37 .33 .31 .36 .31 .36 .31 .35 .31 .30
9 .40 .34 .30 .28 .34 .28 .33 .28 .33 .28 .27
10 .37 .31 .28 .25 .31 .25 .31 .25 .30 .25 .24
LUMINAIRE INPUT WATTS = 205
ANGLE MEAN CP LUMENS
0 5084
5 4974 472
10 4744
15 4560 1296
20 4430
25 4102 1899
30 3781
35 3410 2067
40 2559
45 1567 1207
50 542
55 55 147
60 2
65 0 1
70 0
75 0 0
80 0
85 0 0
90 0
175W ED28 G.E. MH COATED LAMP, LUMEN RATING = 12900 LMS, ADVANCE MAGNETIC BALLAST, CL FINISH TRIM
Coefficients of Utilization
LUMINANCE SUMMARY CD. / SQ. M.
ANGLE MEAN CD/SQ M
45 54182
55 2330
65 0
75 0
85 00
** EFFICIENCY = 54.9% ** CERTIFIED TEST REPORT NO. 2474FR, DATE: FEB 20, 2004
COMPUTED BY LSI PROGRAM **TEST-LITE**
CANDLEPOWER DISTRIBUTION
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE
0-30 3667 28.43 51.74
0-40 5734 44.45 80.9
0-60 7087 54.95 99.99
0-90 7088 54.95 100.00
40-90 1353 10.5 19.1
60-90 0 0 0.01
90-180 0 0 0
0-180 7088 54.95 100.00
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
30°
60°
2,500
1,250
3,750
5,000
CEILING 80% 70% 50% 30%
WALL 70 50 30 10 50 10 50 10 50 10 0
RCR
0 .64 .64 .64 .64 .62 .62 .59 .59 .57 .57 .53
1 .61 .59 .58 .57 .58 .56 .56 .54 .54 .53 .50
2 .58 .56 .53 .52 .55 .51 .53 .50 .51 .49 .47
3 .55 .52 .49 .47 .51 .47 .50 .46 .48 .45 .44
4 .52 .48 .46 .43 .48 .43 .47 .43 .46 .42 .41
5 .50 .45 .42 .40 .45 .40 .44 .39 .43 .39 .38
6 .47 .42 .39 .37 .42 .37 .41 .36 .40 .36 .35
7 .44 .39 .36 .34 .39 .34 .38 .33 .37 .33 .32
8 .42 .36 .33 .31 .36 .31 .36 .31 .35 .31 .30
9 .39 .34 .31 .28 .33 .28 .33 .28 .33 .28 .27
10 .37 .31 .28 .26 .31 .26 .31 .26 .30 .26 .25
LUMINAIRE INPUT WATTS = 290
ANGLE MEAN CP LUMENS
0 7668
5 7576 723
10 7473
15 7346 2071
20 7055
25 6243 2887
30 5410
35 4670 2861
40 3470
45 2195 1667
50 753
55 68 201
60 9
65 3 4
70 0
75 0 0
80 0
85 0 0
90 0
250W ED28 PHILIPS MH COATED LAMP. LUMEN RATING = 19475 LMS, UNIVERSAL MAGNETIC BALLAST, CL FINISH TRIM
Coefficients of Utilization
LUMINANCE SUMMARY CD. / SQ. M.
ANGLE MEAN CD/SQ M
45 75909
55 2904
65 169
75 0
85 0
** EFFICIENCY = 53.5% ** CERTIFIED TEST REPORT NO. 2472FR, DATE: FEB 20, 2004
COMPUTED BY LSI PROGRAM **TEST-LITE**
CANDLEPOWER DISTRIBUTION
ZONAL LUMENS AND PERCENTAGES
ZONE LUMENS % LAMP %LUMINAIRE
0-30 5680 29.17 54.55
0-40 8542 43.86 82.02
0-60 10411 53.46 99.96
0-90 10414 53.48 100
40-90 1872 9.62 17.98
60-90 3 0.02 0.04
90-180 0 0 0
0-180 10414 53.48 100
Zonal Cavity Method - Effective Floor Cavity Reflectance = 20%
30°
60°
3,750
5,625
1,875
7,500
SC = 1.1
SC = 1.1