Lighting Systems LP-10
1BHFPG -JOFBS1FSG-ZUFÜDN4PMJE*OEJSFDU-JHIU51FS'PPU/PNJOBM4FDUJPO
Mounting Accessories
Fixture Lengths & Mounting Locations
Ceiling Grid Kit
CGK
Includes both Standard 1” (2.54cm)
Tee Bar Clip & Slot Tee Clip
Power Feed End Set
Standard Cable Length is 36” (91.44cm)
Straight Cord: LP2EC36
4 Wire Cord*: LP2EC36X4
Cable/Joiner Assembly
Standard Cable Length is 36” (91.44cm)
Single Cable: LP2C36
Single Cable & Cord: LP2CC36
Single Cable & 4 Wire Cord: LP2CC36X4
* use for dimming and/or
emergency battery packs
4’
8’
48” (121.92cm)
4’ 2” (127.00cm)
96” (243.84cm)
8’ 2” (248.92cm)
12’
96” (243.84cm)
12’ 2” (370.84cm)
96” (243.84cm)
16’ 2” (492.76cm)
96” (243.84cm)
96” (243.84cm)
20’ 2” (614.68cm)
96” (243.84cm)
16’
96” (243.84cm)
24’ 2” (736.60cm)
96” (243.84cm)
24’
20’
48” (121.92cm)
48” (121.92cm)
96” (243.84cm)
CANDLEPOWER
ZONE 0 22 45 67 90
DEG.
CANDELAS
180 1977 1977 1977 1977 1977
175 1976 1976 1986 1986 1986
165 1918 1937 1958 1981 1981
155 1790 1836 1891 1991 2005
145 1559 1662 1764 1945 1976
135 1282 1444 1596 1856 1899
125 1028 1247 1493 1806 1761
115 709 1037 1286 1463 1478
105 392 769 845 876 870
95 131 269 236 224 219
90 33 45 25 14 12
85 0 0 0 0 0
75 0 0 0 0 0
65 0 0 0 0 0
55 0 0 0 0 0
45 0 0 0 0 0
35 0 0 0 0 0
25 0 0 0 0 0
15 0 0 0 0 0
500000
000000
Performance
REPORT NO: LRL 300-1Z
CAT NO: LPL2A3T84U
LAMPS: 3 F32T8
LUMENS: 2900
EFFICIENCY: 87.6%
COEFFICIENTS OF UTILIZATION
% EFFECTIVE CEILING CAVITY
REFLECTANCE
80 70 50
WALL REFLECTANCE
70 50 30 70 50 30 50 30 10
083838371 7171494949
176726965 6259424139
269635859 5450373533
363555053 4743333027
457494349 4237292623
552433744 3732252220
648383241 3327231917
744342837 2924201714
841312435 2621181512
938282232 2419171311
10 35 25 20 30 22 17 15 12 10
20% FLOOR CAVITY REFLECTANCE
ROOM CAVITY RATIO
CANDLEPOWER CURVE
DISTRIBUTION
Zone
Lumens % Lamp % Luminaire
0-90 0 0.0 0.0
90-180 7617 87.6 100.0
0-180 7617 87.6 100.0
4-Foot
Module
8-Foot
Module
End Set
Cable/
Joiner
4-Foot Run 11
8-Foot Run 11
12-Foot Run 111 1
16-Foot Run 21 1
20'-Foot Run 121 2
24'-Foot Run 31 2